c. Raise the Limiter Bracket so that it just touches the Diverter Link
and tighten theScrews (2).
NOTE: Raising the Limiter Bracket too high will position the
diverter gate higher, which will obstruct the paper flow and cause
jams.
5. Check the clearance between the Diverter and the cutout in the
Lower Entrance Panel at both sides.
Adjustments/Repairs
The clearance should be minimum 1.0 mm.