Arp 1.9 Downstream Rear Side Cover Replacement - GBC StreamPunch Ultra Service Manual

Table of Contents

Advertisement

ARP 1.9 Downstream Rear Side Cover Replacement

PARTS LIST ON PL 1.2
Use this procedure to remove and install the Downstream Rear Side
Cover.
Removal Procedure
WARNING
Do not perform Repair activities with the power on or electrical
power supplied to the machine. Some machine components contain
dangerous electrical voltages that can result in electrical shock and
possible serious injury.
1. Disconnect the Power Cord.
2. Do GP 6.3 to undock the Punch from the upstream and downstream
equipment.
3. Do ARP 1.6 to remove the Rear Cover.
4. Release the wire saddles and cables.
5. Remove the Screws (7) holding the Downstream Rear Side Cover.
6. Remove the Downstream Rear Side Cover.
Installation Procedure
1. Place the Downstream Rear Side Cover in position.
2. Tighten the Screws (6) holding the Downstream Rear Side Cover.
Adjustments/Repairs
Downstream Rear
Side Cover
3. Install and tighten the Screw at the right side of the Exhaust Fan
Bracket Assembly.
4. Place the Cables in the wire Saddles and cose the wire saddles.
5. Do ARP 1.6 to install the Rear Cover.
6. Do GP 6.4 to dock the Punch to the upstream and downstream
equipment.
7. Connect the Power Cord.
GBC StreamPunch Ultra/Ultra MP
02-03-2017
4-10