Gp 6.2.6 Solenoids Check - GBC StreamPunch Ultra Service Manual

Table of Contents

Advertisement

GP 6.2.6
SOLENOIDS Check
Do the following to check the sensors.
1. At the top level screen,
READY
SINGLE PUNCH
Press and hold both the Up Arrow button and the Down Arrow button
for 5 seconds.
Then while still holding down the Up Arrow button and the Down
Arrow button, press the Enter button.
The Service User Interface screen will appear.
PAPER SIZE
MAX BYPASS
2. Press the down arrow so the return symbol is next to the words
SOLENOIDS.
SENSORS
SOLENOIDS
GBC StreamPunch Ultra/Ultra MP
*
*
11-05-2018
3. Press the ENTER button when the return symbol is next to the word
SOLENOIDS to display the display the SOLENOIDS screen.
L1 L2 L3 L4
L5 L6 L7 L8
4. To check the Solenoids:
NOTE: Door needs to be closed or Interlock Cheater inserted to do
this.
Press the down arrow to scroll through the solenoid options.
The selected solenoid will flash on and off.
Pressing the Enter button will turn ON/OFF the solenoid.
You should hear the Solenoid click when it is cycled.
Repeat as needed to check the other Solenoids.
If a Solenoid does not operate do GP 6.22 Solenoid Cleaning and
Inspection.
5. When you finish checking the Solenoids:
Press the up arrow or down arrow to highlight the BACK option.
Press the ENTER button to display Service mode menu.
Press up or down to display the Previous Menu and Exit Options.
General Procedures and Information
6-31
*
BACK