ARP 2.13
Bypass Diverter Replacement
PARTS LIST ON PL 2.5
Use this procedure to remove and install the Bypass Diverter Assembly.
Removal Procedure
1. Disconnect the Power Cord.
2. Do ARP 1.6 to remove the Rear Cover.
3. Remove the E-clip from the Diverter Shaft on the front side.
4. Remove the M4 screws (2) from the Diverter Shaft on the rear side.
5. Remove the E-clip from the Diverter Shaft on the rear side.
Adjustments/Repairs
6. Slide the Diverter Assembly to the back side and remove the part.
Installation Procedure
1. Slide the Diverter Assembly into position through to the rear side.
2. Install the E-clip on the Diverter Shaft at the rear side.
3. Install the M4 screws (2) on the Diverter Shaft at the rear side.
4. Install the E-clip on the Diverter Shaft at the front side.
5. Do ARP 1.6 to install the Rear Cover.
6. Connect the Power Cord.
7. Do ADJ 1.2 Diverter Solenoid Adjustment.