Arp 2.6 Lower Exit Panel Replacement - GBC StreamPunch Ultra Service Manual

Table of Contents

Advertisement

ARP 2.6 Lower Exit Panel Replacement

PARTS LIST ON PL 2.1
Use this procedure to remove and install the Lower Exit Panel.
Removal Procedure
WARNING
Do not perform Repair activities with the power on or electrical
power supplied to the machine. Some machine components contain
dangerous electrical voltages that can result in electrical shock and
possible serious injury.
1. Disconnect the Power Cord.
2. Open the Front Door.
3. Remove the screw for ground strap.
4. Remove the E-clips (2) from the Shaft.
GBC StreamPunch Ultra/Ultra MP
5. Slide the Shaft out of place.
6. Remove the Lower Exit Panel.
Installation Procedure
1. Place the Lower Exit Panel in position.
2. Slide the Shaft into place.
3. Install the E-clips (2) on the ends of the Shaft.
4. Close the Front Door.
5. Connect the Power Cord.