ARP 2.28.3 Accel Sensor (S5) Replacement
Use this procedure to remove and install the Sensor and Bracket
Assembly for the Accel Sensor (S5).
1. Disconnect the Power Cord.
2. Do GP 6.3 to undock the Punch from the upstream and downstream
equipment.
3. Disconnect the sensor connector at the Sensor.
4. Remove the Barrel Screw that secures the Sensor to the sheet metal
part.
Accel Sensor (S5)
5. Remove the old Sensor.
6. Place the new Sensor in position, then install the Barrell Screw.
7. Do GP 6.4 to dock the Punch to the upstream and downstream
equipment.
8. Connect the Power Cord.
GBC StreamPunch Ultra/Ultra MP
02-03-2017
4-67
Adjustments/Repairs