GBC StreamPunch Ultra Service Manual page 26

Table of Contents

Advertisement

Chip Tray Out
This message is displayed when the Chip tray is removed from the
machine or when the chip tray is not fully inserted.
Use this procedure when the Chip Tray Out message is displayed when
the Chip tray is inserted.
1. Open the Front door and insert the Chip Tray firmly.
This clears the fault.
Yes- Return to normal operation; No- Go to step 2
2. Inspect if the Spring Clip of the Chip tray home switch. If the Spring
Clip is broken, do ARP 3.2 Chip Tray Home Switch Replacement.
This clears the fault.
Yes- Return to normal operation; No- Go to step 3
3. Do GP 6.2.12 Firmware Upgrade procedure to re-flash the Firmware
for Advanced Punch Pro,
Re-flashing the firmware clears the fault.
Yes- Return to normal operation; No- Go to step 4
4. Do ARP 3.2, Replace Chip Tray Home Switch,
This clears the fault.
Yes- Return to normal operation; No- Go to step 5
5. Replace Cable 7715485 (See Section 7 Wiring).
This clears the fault.
Yes- Return to normal operation;
No- Do ARP 5.1 Main Control Board Replacement to Replace the
Main Control Board (PL 6.1).
GBC StreamPunch Ultra/Ultra MP
Chip Tray Out message is not displayed when the Chip tray is
out
This message is displayed when the Chip Tray Out message is not
displayed when the Chip tray is out.
1. Make sure the (2) spade connectors to the Chip tray home switch is
securely inserted. (see ARP 3.2 for details)
Connectors are securely connected.
Yes- Go to step 2;
2. Do ARP 1.6 to remove the Rear Cover and check the 7715485 cable
is connected to J27 at the Main Control Board (Section 7 Wiring)
See the Sensor Cables table on page 2-35 for cable numbers.
The connection is good.
Yes- Go to step 3;
No- Make the connection and return to normal operation.
3. Do GP 6.2.12 Firmware Upgrade procedure to re-flash the Firmware
for Advanced Punch Pro,
Re-flashing the firmware clears the fault.
Yes- Return to normal operation; No- Go to step 4
4. Do ARP 3.2, Replace Chip Tray Home Switch,
This clears the fault.
Yes- Return to normal operation; No- Go to Step 5
5. Replace Cable 7715485.
This clears the fault.
Yes-
Return to normal operation
No-
Do ARP 5.1 Main Control Board Replacement to Replace the
Main Control Board (PL 6.1).
11-05-2018
2-9
No- Securely connect the (2) spade connectors
RTPS