Arp 2.28.4 Align Home Sensor (S28) Replacement - GBC StreamPunch Ultra Service Manual

Table of Contents

Advertisement

ARP 2.28.4 Align Home Sensor (S28) Replacement

Use this procedure to remove and install the Sensor and Bracket
Assembly for the Align Home Sensor (S28).
1. Disconnect the Power Cord.
2. Do GP 6.3 to undock the Punch from the upstream and downstream
equipment.
3. Disconnect the Sensor Wire Connector from the Sensor.
4. Remove the M3 Screws (2) that secure the Sensor to the Bracket.
Adjustments/Repairs
Sensor Wire
Connector
Sensor
Bracket
Screws (2)
5. Remove the Sensor Sub-assembly.
6. Place the new Sensor in position.
7.
Tighten the M3 Screws (2) that secure the Sensor to the Bracket.
8. Connect the Sensor Connector to the Sensor.
9. Do GP 6.4 to dock the Punch to the upstream and downstream
equipment.
10. Connect the AC power cord
GBC StreamPunch Ultra/Ultra MP
02-03-2017
4-68
Sensor
Sub-assembly

Hide quick links: