7. Blower Motor Unit Assembly
A: REMOVAL
1) Disconnect the ground cable from the battery.
2) Remove the glove box. <Ref. to EI-43, REMOV-
AL, Glove Box.>
3) Loosen the nut to remove the support beam
stay.
4) Disconnect the blower motor connector.
5) Disconnect the power transistor or blower resis-
tor connector.
6) Loosen the bolt and nut to remove the blower
motor unit assembly.
Blower Motor Unit Assembly
HVAC SYSTEM (HEATER, VENTILATOR AND A/C)
B: INSTALLATION
Install in the reverse order of removal.
Tightening torque:
Refer to "COMPONENT" of "General Descrip-
tion". <Ref. to AC-5, HEATER COOLING
UNIT, COMPONENT, General Description.>
and <Ref. to AC-7, BLOWER MOTOR UNIT,
COMPONENT, General Description.>
C: INSPECTION
Connect the positive (+) lead from the battery to the
motor connector terminal 1, and the negative (–)
lead to terminal 2. Make sure the motor runs
smoothly.
AC-00218
AC-00614
AC-00615
AC-00616
AC-25