asieps_tobira_IM_US.book 33 ページ 2012年1月17日 火曜日 午後3時48分
26.Room Light
A: REMOVAL
1) Disconnect the ground cable from the battery.
2) Remove the lens (A) and mounting screws (B).
(B)
3) Disconnect the harness connector and remove
the room light.
B: INSTALLATION
Install in the reverse order of removal.
C: INSPECTION
1. ROOM LIGHT BULB
1) Visually check the bulb for blow out.
2) Check the bulb specification. <Ref. to LI-2,
SPECIFICATION, General Description.>
3) If NG, replace the bulb with a new part.
2. ROOM LIGHT SWITCH
Measure the resistance between room light termi-
nals.
3 2 1
Switch position
Terminal No.
OFF
ON
1 and 3
DOOR
1 and 2
Room Light
(B)
(A)
LI-00040
R52
LI-00041
Standard
—
1 MΩ or more
1.5±0.5 Ω
1.5±0.5 Ω
LI-33
LIGHTING SYSTEM