asieps_tobira_IM_US.book 8 ページ 2012年1月17日 火曜日 午後3時48分
SECURITY AND LOCKS
2. Door Lock Control System
A: WIRING DIAGRAM
1. DOOR LOCK CONTROL
<Ref. to WI-168, WIRING DIAGRAM, Keyless Entry System.>
B: INSPECTION
1. SYMPTOM CHART
Symptom
The door lock control system does
not operate.
The door lock switch does not operate. Check the door lock switch and circuit.
A specific door lock actuator does not
operate.
2. CHECK FUSE
Step
1
CHECK FUSE.
Remove and visually check the fuses No. 2 (in
the main fuse box) and No. 3 (in the fuse & relay
box).
Door Lock Control System
Repair order
1. Check the fuse.
2. Check the power supply and ground circuit for
body integrated unit.
3. Check the door lock switch and the circuit.
4. Check the door lock actuator and the circuit.
Check the door lock actuator and circuit.
Check
Is the fuse blown out?
SL-8
Reference
<Ref. to SL-8, CHECK FUSE,
INSPECTION, Door Lock Control
System.>
<Ref. to SL-9, CHECK POWER
SUPPLY AND GROUND CIRCUIT,
INSPECTION, Door Lock Control
System.>
<Ref. to SL-9, CHECK DOOR LOCK
SWITCH AND CIRCUIT, INSPEC-
TION, Door Lock Control System.>
<Ref. to SL-10, CHECK DOOR
LOCK ACTUATOR AND CIRCUIT,
INSPECTION, Door Lock Control
System.>
<Ref. to SL-9, CHECK DOOR LOCK
SWITCH AND CIRCUIT, INSPEC-
TION, Door Lock Control System.>
<Ref. to SL-10, CHECK DOOR
LOCK ACTUATOR AND CIRCUIT,
INSPECTION, Door Lock Control
System.>
Yes
No
Replace the fuse
Check the power
with a new part.
supply and ground
circuit. <Ref. to SL-
9, CHECK
POWER SUPPLY
AND GROUND
CIRCUIT,
INSPECTION,
Door Lock Control