2 Parameters
2.2 List of parameters
39:
40:
41:
42:
43:
44:
45:
46:
47:
Dependency:
Only the unit of the technology controller parameters are switched over (unit group 9_1).
Refer to: p0596
Note:
When switching over from % into another unit, the following sequence applies:
- set p0596
- set p0595 to the required unit
p0596
Technological unit reference quantity / Tech unit ref qty
Access level: 1
Can be changed: T
Unit group: -
Min
0.01
Description:
Sets the reference quantity for the technological units.
When changing over using changeover parameter p0595 to absolute units, all of the parameters involved refer to the
reference quantity.
Dependency:
Refer to: p0595
Notice:
When changing over from one technological unit into another, or when changing the reference parameter, a
changeover is not made.
p0601[0...n]
Motor temperature sensor type / Mot_temp_sens type
Access level: 2
Can be changed: C(3), U, T
Unit group: -
Min
0
Description:
Sets the sensor type for the motor temperature monitoring.
Value:
0:
1:
2:
4:
6:
Dependency:
A thermal motor model is calculated corresponding to p0612.
Caution:
For p0601 = 2, 6:
If the motor temperature sensor is not connected but another encoder, then the temperature adaptation of the motor
resistances must be switched out (p0620 = 0). Otherwise, in controlled-loop operation, torque errors will occur that
will mean that the motor will not be able to be stopped.
Note:
For p0601 = 1:
Tripping resistance = 1650 Ohm. Wire breakage and short-circuit monitoring.
p0604[0...n]
Mot_temp_mod 2/sensor alarm threshold / Mod 2/sens A_thr
Access level: 2
Can be changed: C(3), U, T
Unit group: 21_1
Min
0.0 [°C]
Description:
Sets the alarm threshold for monitoring the motor temperature for motor temperature model 2 or KTY/PT1000.
94
BTU/min
BTU/h
mbar
inch wg
ft wg
m wg
% r.h.
g/kg
ppm
No sensor
PTC alarm & timer
KTY84
Bimetallic NC contact alarm & timer
PT1000
Calculated: -
Scaling: -
Unit selection: -
Max
340.28235E36
Calculated: -
Scaling: -
Unit selection: -
Max
6
Calculated: -
Scaling: -
Unit selection: p0505
Max
240.0 [°C]
SINAMICS G120 Control Units CU240B-2/CU240E-2
Data type: FloatingPoint32
Dyn. index: -
Func. diagram: -
Factory setting
1.00
Data type: Integer16
Dyn. index: MDS
Func. diagram: 8016
Factory setting
0
Data type: FloatingPoint32
Dyn. index: MDS
Func. diagram: 8016
Factory setting
130.0 [°C]
List Manual (LH11), 01/2016, A5E33839529