Siemens SINAMICS G120 List Manual page 180

Hide thumbs Also See for SINAMICS G120:
Table of Contents

Advertisement

2 Parameters
2.2 List of parameters
10
11
12
13
r1205.0...15
CO/BO: Flying restart vector control status / FlyRest vector st
Access level: 4
Can be changed: -
Unit group: -
Min
-
Description:
Display and connector output for the status for checking and monitoring flying restart states in the vector control
mode.
Bit field:
Bit
00
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
Note:
For bit 00 ... 09:
Used to control internal sequences during the flying restart.
Depending on the motor type (p0300), the number of active bits differs.
For bits 10 ... 15:
Are used to monitor the flying restart sequence.
p1206[0...9]
Automatic restart faults not active / AR fault not act
Access level: 3
Can be changed: U, T
Unit group: -
Min
0
Description:
Sets faults for which automatic restart should not be effective.
Dependency:
The setting is only effective for p1210 = 6, 16, 26.
Refer to: p1210
p1210
Automatic restart mode / AR mode
Access level: 2
Can be changed: U, T
Unit group: -
Min
0
Description:
Sets the automatic restart mode (AR).
The parameters must be saved in the non-volatile memory p0971 = 1 in order that the setting becomes effective.
180
Search in the positive direction
Stop after positive direction
Stop after negative direction
No result
Signal name
Speed adaptation circuit record angle
Speed adaptation circuit set gain to 0
Isd channel enable
Speed control switched out
Quadrature arm switched in
Special transformation active
Speed adaptation circuit set I comp to 0
Current control on
Isd_set = 0 A
Frequency held
Search in the positive direction
Search Started
Current impressed
Search interrupted
Speed adaptation circuit deviation = 0
Speed control activated
Yes
Yes
Yes
Yes
Calculated: -
Scaling: -
Unit selection: -
Max
-
1 signal
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Calculated: -
Scaling: -
Unit selection: -
Max
65535
Calculated: -
Scaling: -
Unit selection: -
Max
26
SINAMICS G120 Control Units CU240B-2/CU240E-2
No
No
No
No
Data type: Unsigned32
Dyn. index: -
Func. diagram: -
Factory setting
-
0 signal
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
Data type: Unsigned16
Dyn. index: -
Func. diagram: -
Factory setting
0
Data type: Integer16
Dyn. index: -
Func. diagram: -
Factory setting
0
List Manual (LH11), 01/2016, A5E33839529
-
-
-
-