2 Parameters
2.2 List of parameters
p20302
NOT 4 run-time group / NOT 4 RTG
Access level: 3
Can be changed: T
Unit group: -
Min
1
Description:
Setting parameter for the run-time group in which the instance NOT 4 of the inverter is to be called.
Value:
1:
2:
3:
4:
5:
6:
9999: Do not calculate
p20303
NOT 4 run sequence / NOT 4 RunSeq
Access level: 3
Can be changed: T
Unit group: -
Min
0
Description:
Setting parameter for the run sequence of instance NOT 4 within the run-time group set in p20302.
Note:
The function blocks with a lower run sequence value are calculated before function blocks with a higher run
sequence value.
p20304
BI: NOT 5 input I / NOT 5 input I
Access level: 3
Can be changed: T
Unit group: -
Min
-
Description:
Sets the signal source of input quantity I of instance NOT 5 of the inverter.
r20305
BO: NOT 5 inverted output / NOT 5 inv output
Access level: 3
Can be changed: -
Unit group: -
Min
-
Description:
Display parameter for the inverted output of instance NOT 5 of the inverter.
p20306
NOT 5 run-time group / NOT 5 RTG
Access level: 3
Can be changed: T
Unit group: -
Min
1
Description:
Setting parameter for the run-time group in which the instance NOT 5 of the inverter is to be called.
Value:
1:
2:
3:
4:
5:
512
Run-time group 1
Run-time group 2
Run-time group 3
Run-time group 4
Run-time group 5
Run-time group 6
Run-time group 1
Run-time group 2
Run-time group 3
Run-time group 4
Run-time group 5
Calculated: -
Scaling: -
Unit selection: -
Max
9999
Calculated: -
Scaling: -
Unit selection: -
Max
32000
Calculated: -
Scaling: -
Unit selection: -
Max
-
Calculated: -
Scaling: -
Unit selection: -
Max
-
Calculated: -
Scaling: -
Unit selection: -
Max
9999
SINAMICS G120 Control Units CU240B-2/CU240E-2
Data type: Integer16
Dyn. index: -
Func. diagram: 7216
Factory setting
9999
Data type: Unsigned16
Dyn. index: -
Func. diagram: 7216
Factory setting
770
Data type: U32 / Binary
Dyn. index: -
Func. diagram: 7216
Factory setting
0
Data type: Unsigned32
Dyn. index: -
Func. diagram: 7216
Factory setting
-
Data type: Integer16
Dyn. index: -
Func. diagram: 7216
Factory setting
9999
List Manual (LH11), 01/2016, A5E33839529