Siemens SINAMICS G120 List Manual page 756

Hide thumbs Also See for SINAMICS G120:
Table of Contents

Advertisement

1 ms
t_System relative
0 ... 4294967295 [ms]
p0969 (0)
32 bit counter,
free running
III
[8065.1]
Operating time
1 = Acknowledge fault
p2103 ... p2105
r2138
r2138.7
[2546.7]
POWER ON
Faults ackn DO
p3981
1 = External fault 1
(F07860) effective
p2106
r2138
r2138
.13
[2546.7]
1 = External fault 2
(F07861) effective
p2107
r2138
r2138.14
[2546.7]
1 = External fault 3
(F07862) effective
p2108, p3110 ... p3112
r2138
r2138.15
[2546.7]
<1>
This fault is overwritten when "more recent" faults occur.
<2>
The buffer parameters are cyclically updated in the background (refer to the status signal in r2139).
1
2
Diagnostics
Fault buffer
LED "RDY" [= red for fault]
Act fault code
r2131
0 = "No fault present"
<2>
Fault code
Fault value
Fault times
r0949[0] [I32]
Fault
1
r0945[0]
r2133[0] [Float]
r0949[1] [I32]
r0945[1]
Fault
2
r2133[1] [Float]
Actual
fault case
r0949[7] [I32]
r0945[7]
Fault
8
r2133[7] [Float]
<1>
Faults
Acknowledging
r0949[8] [I32]
Fault
1
r0945[8]
r2133[8] [Float]
r0949[9] [I32]
Fault
2
r0945[9]
r2133[9] [Float]
1. Acknow-
ledged
fault case
r0949[15] [I32]
Fault
8
r0945[15]
r2133[15] [Float]
r0949[56] [I32]
Fault
1
r0945[56]
r2133[56] [Float]
r0949[57] [I32]
Fault
2
r0945[57]
r2133[57] [Float]
7. Acknow-
ledged
fault case
[oldest]
r0949[63] [I32]
Fault
8
r0945[63]
r2133[63] [Float]
3
4
Act fault val
Comp_no act
r3131
r3132
Diagnostic
Fault time
Fault time
Component
attribute
"received"
"removed"
fault
fault
r0948[0] [ms]
r2109[0] [ms]
3120[0]
r3122[0]
r2130[0] [d]
r2136[0] [d]
r0948[1] [ms]
r2109[1] [ms]
3120[1]
r3122[1]
r2130[1] [d]
r2136[1] [d]
RESET
r0948[7] [ms]
r2109[7] [ms]
3120[7]
r3122[7]
r2130[7] [d]
r2136[7] [d]
r0948[8] [ms]
r2109[8] [ms]
3120[8]
r3122[8]
r2130[8] [d]
r2136[8] [d]
r0948[9] [ms]
r2109[9] [ms]
3120[9]
r3122[9]
r2130[9] [d]
r2136[9] [d]
r0948[15] [ms]
r2109[15] [ms]
3120[15]
r3122[15]
r2130[15] [d]
r2136[15] [d]
r0948[56] [ms]
r2109[56] [ms]
3120[56]
r3122[56]
r2130[56] [d]
r2136[56] [d]
r0948[57] [ms]
r2109[57] [ms]
3120[57]
r3122[57]
r2130[57] [d]
r2136[57] [d]
r0948[63] [ms]
r2109[63] [ms]
3120[63]
r3122[63]
r2130[63] [d]
r2136[63] [d]
5
6
fp_8060_97_51.vsd
09.12.2015
Counter
16 bit
Fault cases qty
Fault case
0 ... 65535
III
appears
p0952 (0)
RESET
Delete fault buffer
p0952 = 0:
Fault buffer is deleted/
r0945 = 0
cleared
r0948 = 0
r0949 = 0
r2109 = 0
1
r2130 = 0
r2133 = 0
r2136 = 0
r3120 = 0
Fault buffer change [8065.6]
r3122 = 0
16 bit counter,
Fault appears
free running
Fault buff change
Fault disappears
1
III
Fault case
RESET
acknowl.
POWER ON
ZSW fault/alarm 1
r2139
r2139
.3
1 = Fault present
r2139.15
1 = Fault gone/can be acknowledged
[2548.2]
Fault responses to the sequence control
7
Function diagram
G120 CU240B/E-2
V4.7.6
Automatic
r0944
8
- 8060 -

Advertisement

Table of Contents
loading

Table of Contents