2 Parameters
2.2 List of parameters
p9851
SI STO debounce time (processor 2) / SI STO t_debou P2
PM230_STO
Access level: 3
PM240
Can be changed: C(95)
PM250
Unit group: -
PM260
Min
CU240E-2
0.00 [µs]
CU240E-2_DP
CU240E-2 PN
CU240E-2_F
CU240E-2_PN_F
CU240E-2_DP_F
Description:
Sets the debounce time for the failsafe digital inputs used to control the "STO" function.
The debounce time is rounded to whole milliseconds.
Dependency:
Refer to: p9651
Notice:
This parameter is overwritten by the copy function of the safety functions integrated in the drive.
Note:
Rounding effects can occur in the last decimal place of the parameterized time.
The debounce time is rounded to whole milliseconds. It specifies the maximum duration of a fault pulse at the fail-
safe digital inputs with no reaction/influence on the selection or deselection of the Safety Basic Functions.
Example:
Debounce time = 1 ms: Fault pulses of 1 ms are filtered; only pulses longer than 2 ms are processed.
Debounce time = 3 ms: Fault pulses of 3 ms are filtered; only pulses longer than 4 ms are processed.
r9871
SI common functions (processor 2) / SI common fct P2
PM230_STO
Access level: 3
CU240E-2_DP
Can be changed: -
CU240E-2 PN
Unit group: -
CU240E-2_PN_F
Min
CU240E-2_DP_F
-
Description:
Displays the supported Safety Integrated monitoring functions.
Processor 2 determines this display.
Bit field:
Bit
00
06
Dependency:
Refer to: r9771
Note:
STO: Safe Torque Off
r9871
SI common functions (processor 2) / SI common fct P2
PM230_STO
Access level: 3
CU240E-2
Can be changed: -
CU240E-2_F
Unit group: -
Min
-
Description:
Displays the supported Safety Integrated monitoring functions.
Processor 2 determines this display.
Bit field:
Bit
00
Dependency:
Refer to: r9771
Note:
STO: Safe Torque Off
446
Signal name
STO supported via terminals
Basic Functions PROFIsafe supported
Signal name
STO supported via terminals
Calculated: -
Scaling: -
Unit selection: -
Max
100000.00 [µs]
Calculated: -
Scaling: -
Unit selection: -
Max
-
1 signal
Yes
Yes
Calculated: -
Scaling: -
Unit selection: -
Max
-
1 signal
Yes
SINAMICS G120 Control Units CU240B-2/CU240E-2
Data type: FloatingPoint32
Dyn. index: -
Func. diagram: -
Factory setting
0.00 [µs]
Data type: Unsigned32
Dyn. index: -
Func. diagram: 2804
Factory setting
-
0 signal
No
No
Data type: Unsigned32
Dyn. index: -
Func. diagram: 2804
Factory setting
-
0 signal
No
List Manual (LH11), 01/2016, A5E33839529
FP
2804
-
FP
2804

Advertisement