p1070[0...n]
CI: Main setpoint / Main setpoint
CU240B-2_DP
Access level: 3
CU240E-2_DP
Can be changed: T
CU240E-2 PN
Unit group: -
CU240E-2_PN_F
Min
CU240E-2_DP_F
-
Description:
Sets the signal source for the main setpoint.
Examples:
r1024: Fixed speed setpoint effective
r1050: Motor. potentiometer setpoint after the ramp-function generator
Dependency:
Refer to: p1071, r1073, r1078
Notice:
The parameter may be protected as a result of p0922 or p2079 and cannot be changed.
p1070[0...n]
CI: Main setpoint / Main setpoint
CU240B-2
Access level: 3
CU240E-2
Can be changed: T
CU240E-2_F
Unit group: -
Min
-
Description:
Sets the signal source for the main setpoint.
Examples:
r1024: Fixed speed setpoint effective
r1050: Motor. potentiometer setpoint after the ramp-function generator
Dependency:
Refer to: p1071, r1073, r1078
Notice:
The parameter may be protected as a result of p0922 or p2079 and cannot be changed.
p1071[0...n]
CI: Main setpoint scaling / Main setp scal
Access level: 3
Can be changed: T
Unit group: -
Min
-
Description:
Sets the signal source for scaling the main setpoint.
r1073
CO: Main setpoint effective / Main setpoint eff
Access level: 3
Can be changed: -
Unit group: 3_1
Min
- [rpm]
Description:
Displays the effective main setpoint.
The value shown is the main setpoint after scaling.
SINAMICS G120 Control Units CU240B-2/CU240E-2
List Manual (LH11), 01/2016, A5E33839529
Calculated: -
Scaling: p2000
Unit selection: -
Max
-
Calculated: -
Scaling: p2000
Unit selection: -
Max
-
Calculated: -
Scaling: PERCENT
Unit selection: -
Max
-
Calculated: -
Scaling: p2000
Unit selection: p0505
Max
- [rpm]
2 Parameters
2.2 List of parameters
Data type: U32 / FloatingPoint32
Dyn. index: CDS, p0170
Func. diagram: 3001, 3030
Factory setting
[0] 2050[1]
[1] 0
[2] 0
[3] 0
Data type: U32 / FloatingPoint32
Dyn. index: CDS, p0170
Func. diagram: 3001, 3030
Factory setting
[0] 755[0]
[1] 0
[2] 0
[3] 0
Data type: U32 / FloatingPoint32
Dyn. index: CDS, p0170
Func. diagram: 3001, 3030
Factory setting
1
Data type: FloatingPoint32
Dyn. index: -
Func. diagram: 3030
Factory setting
- [rpm]