Siemens SINAMICS G120 List Manual page 506

Hide thumbs Also See for SINAMICS G120:
Table of Contents

Advertisement

2 Parameters
2.2 List of parameters
Index:
[0] = Input X
[1] = Setting value SV
p20257
INT 0 upper limit value LU / INT 0 upper lim LU
Access level: 3
Can be changed: T
Unit group: -
Min
-340.28235E36
Description:
Sets the upper limit value LU of instance INT 0 of the integrator.
p20258
INT 0 lower limit value LL / INT 0 lower lim LL
Access level: 3
Can be changed: T
Unit group: -
Min
-340.28235E36
Description:
Sets the lower limit value LL of instance INT 0 of the integrator.
p20259
INT 0 integrating time constant in ms / INT 0 T_Integr ms
Access level: 3
Can be changed: T
Unit group: -
Min
0.00
Description:
Sets the integrating time constant Ti in milliseconds of instance INT 0 of the integrator.
p20260
BI: INT 0 accept setting value S / INT 0 acc set val
Access level: 3
Can be changed: T
Unit group: -
Min
-
Description:
Sets the signal source for the "accept setting value" signal of instant INT 0 of the integrator.
r20261
CO: INT 0 output Y / INT 0 output Y
Access level: 3
Can be changed: -
Unit group: -
Min
-
Description:
Display parameter for output quantity Y of instance INT 0 of the integrator.
If LL>= LU, then the output quantity Y = LU.
r20262
BO: INT 0 integrator at the upper limit QU / INT 0 QU
Access level: 3
Can be changed: -
Unit group: -
Min
-
Description:
Display parameter for the signal QU that output quantity Y of instance INT 0 of the integrator has reached the upper
limit value LU.
506
Calculated: -
Scaling: -
Unit selection: -
Max
340.28235E36
Calculated: -
Scaling: -
Unit selection: -
Max
340.28235E36
Calculated: -
Scaling: -
Unit selection: -
Max
340.28235E36
Calculated: -
Scaling: -
Unit selection: -
Max
-
Calculated: -
Scaling: PERCENT
Unit selection: -
Max
-
Calculated: -
Scaling: -
Unit selection: -
Max
-
SINAMICS G120 Control Units CU240B-2/CU240E-2
Data type: FloatingPoint32
Dyn. index: -
Func. diagram: 7264
Factory setting
0.0000
Data type: FloatingPoint32
Dyn. index: -
Func. diagram: 7264
Factory setting
0.0000
Data type: FloatingPoint32
Dyn. index: -
Func. diagram: 7264
Factory setting
0.00
Data type: U32 / Binary
Dyn. index: -
Func. diagram: 7264
Factory setting
0
Data type: FloatingPoint32
Dyn. index: -
Func. diagram: 7264
Factory setting
-
Data type: Unsigned32
Dyn. index: -
Func. diagram: 7264
Factory setting
-
List Manual (LH11), 01/2016, A5E33839529

Advertisement

Table of Contents
loading

Table of Contents