Note:
If value = 0:
No terminal assigned, safety function always selected.
If value = 255:
No terminal assigned, safety function always deselected.
F-DI: Failsafe Digital Input
SDI: Safe Direction (safe motion direction)
p10031
SI Motion SDI negative input terminal (processor 1) / SI SDI neg F-DI P1
PM240
Access level: 3
PM250
Can be changed: C(95)
PM260
Unit group: -
CU240E-2_F
Min
CU240E-2_PN_F
0
CU240E-2_DP_F
Description:
Sets the fail-safe digital input (F-DI) for the "SDI negative" function.
Value:
0:
1:
2:
3:
255:
Note:
If value = 0:
No terminal assigned, safety function always selected.
If value = 255:
No terminal assigned, safety function always deselected.
F-DI: Failsafe Digital Input
SDI: Safe Direction (safe motion direction)
r10049
SI Motion F-DI monitoring status (processor 1) / SI F-DI status P1
PM240
Access level: 3
PM250
Can be changed: -
PM260
Unit group: -
CU240E-2_F
Min
CU240E-2_PN_F
-
CU240E-2_DP_F
Description:
Displays the monitoring status of the fail-safe digital inputs (F-DI).
The F-DIs that are being used by the Safety Integrated functions are displayed.
If the module used has fewer than 3 F-DIs, "Freely available" is displayed for the F-DIs which are not in use.
Bit field:
Bit
00
01
02
Dependency:
p10006 / p10106
p10022 / p10122
p10023 / p10123
p10026 / p10126
p10030 / p10130
p10031 / p10131
p10050 / p10150
Refer to: r10149
SINAMICS G120 Control Units CU240B-2/CU240E-2
List Manual (LH11), 01/2016, A5E33839529
Static selected
F-DI 0
F-DI 1
F-DI 2
Static deselected
Signal name
F-DI 0
F-DI 1
F-DI 2
Calculated: -
Scaling: -
Unit selection: -
Max
255
Calculated: -
Scaling: -
Unit selection: -
Max
-
1 signal
Safety monitored
Safety monitored
Safety monitored
2 Parameters
2.2 List of parameters
Data type: Integer16
Dyn. index: -
Func. diagram: -
Factory setting
0
Data type: Unsigned32
Dyn. index: -
Func. diagram: -
Factory setting
-
0 signal
Freely available
Freely available
Freely available