Siemens SINAMICS G120 List Manual page 437

Hide thumbs Also See for SINAMICS G120:
Table of Contents

Advertisement

r9773.0...31
CO/BO: SI status (processor 1 + processor 2) / SI status P1+P2
PM230_STO
Access level: 2
PM240
Can be changed: -
PM250
Unit group: -
PM260
Min
CU240E-2
-
CU240E-2_DP
CU240E-2 PN
CU240E-2_F
CU240E-2_PN_F
CU240E-2_DP_F
Description:
Display and BICO output for the Safety Integrated status on the drive (processor 1 + processor 2).
Bit field:
Bit
00
01
30
31
Note:
This status is formed from the AND operation of the relevant status of the two monitoring channels.
r9776
SI diagnostics / SI diag
PM230_STO
Access level: 3
PM240
Can be changed: -
PM250
Unit group: -
PM260
Min
CU240E-2
-
CU240E-2_DP
CU240E-2 PN
CU240E-2_F
CU240E-2_PN_F
CU240E-2_DP_F
Description:
The parameter is used for diagnostics.
Bit field:
Bit
00
01
02
Note:
For bit 00 = 1:
At least one Safety parameter has been changed that will only take effect after a POWER ON.
For bit 01 = 1:
Safety functions (basic functions or extended functions) have been enabled and are active.
For bit 02 = 1:
A safety-relevant component has been replaced. Data save required (p0977 = 1 or p0971 = 1 or "copy RAM to
ROM").
SINAMICS G120 Control Units CU240B-2/CU240E-2
List Manual (LH11), 01/2016, A5E33839529
Signal name
STO selected in drive
STO active in drive
PM terminals switch-off signal paths must
be tested
Switch-off signal paths must be tested
Signal name
Safety parameter changed POWER ON
required
Safety functions enabled
Safety component replaced and data save
required
Calculated: -
Scaling: -
Unit selection: -
Max
-
1 signal
Yes
Yes
Yes
Yes
Calculated: -
Scaling: -
Unit selection: -
Max
-
1 signal
Yes
Yes
Yes
2 Parameters
2.2 List of parameters
Data type: Unsigned32
Dyn. index: -
Func. diagram: 2804
Factory setting
-
0 signal
No
No
No
No
Data type: Unsigned32
Dyn. index: -
Func. diagram: -
Factory setting
-
0 signal
No
No
No
FP
2804
2804
-
2810
FP
-
-
-
437