2 Parameters
2.2 List of parameters
Bit field:
Bit
00
01
05
06
14
15
16
18
20
22
24
25
Dependency:
Not visible with application class: "Standard Drive Control" (SDC, p0096 = 1)
Note:
For bit 01:
When the bit is set, the I component of the speed controller is kept when changing into the open-loop controlled
mode.
For bit 16:
When the bit is set, the integral component of the speed controller is only held if it reaches the torque limit.
For bit 20:
The acceleration model for the speed setpoint is only active for encoderless vector control if p1496 is not zero.
For bit 25:
When the bit is set, for high dynamic starting in the I/f mode, the acceleration precontrol torque smoothing only has a
short minimum time (4 ms).
p1401[0...n]
Flux control configuration / Flux ctrl config
Access level: 4
Can be changed: U, T
Unit group: -
Min
-
Description:
Sets the configuration for flux setpoint control
Bit field:
Bit
00
01
02
06
07
Dependency:
Not visible with application class: "Standard Drive Control" (SDC, p0096 = 1)
Note:
For bit 00 (not for permanent-magnet synchronous motors):
Initially, the flux is only established with a low rate of rise when magnetizing the induction motor. The flux setpoint
p1570 is reached again at the end of the magnetizing time p0346.
For bit 01 (not for permanent-magnet synchronous motors):
Initially, the flux is only established with a low rate of rise when magnetizing the induction motor. The flux setpoint
p1570 is reached again at the end of the magnetizing time p0346. When quick magnetizing (p1401.6 = 1) is selected,
soft starting is internally de-activated and alarm A07416 is displayed.
The flux differentiation can be switched out if a significant ripple occurs in the field-generating current setpoint (r0075)
when entering the field weakening range. However, this is not suitable for fast acceleration operations because then,
the flux decays more slowly and the voltage limiting responds.
For bit 02 (not for permanent-magnet synchronous motors):
The flux build-up control operates during the magnetizing phase p0346 of the induction motor. If it is switched out, a
constant current setpoint is injected and the flux is built up corresponding to the rotor time constant. When quick
magnetizing (p1401.6 = 1) is selected and when flux build-up control is de-energized alarm A07416 is displayed.
212
Signal name
Automatic Kp/Tn adaptation active
Sensorless vector control freeze I comp
Kp/Tn adaptation active
Free Tn adaptation active
Torque pre-control
Sensorless vector control speed pre-control Yes
I component for limiting
Moment of inertia estimator active
Acceleration model
Obtain moment of inertia estimator value for
pulse inhibit
Accelerated moment of inertia estimator
active
Acceleration torque instantaneous in the I/f
mode
Signal name
Flux setpoint soft starting active
Flux setpoint differentiation active
Flux build-up control active
Quick magnetizing
Pre-control speed limitation
1 signal
Yes
Yes
Yes
Yes
Always active
Enable
Yes
ON
Yes
Yes
Yes
Calculated: -
Scaling: -
Unit selection: -
Max
-
1 signal
Yes
Yes
Yes
Yes
Yes
SINAMICS G120 Control Units CU240B-2/CU240E-2
0 signal
No
No
No
No
For n_ctrl enab
No
Hold
No
OFF
No
No
No
Data type: Unsigned16
Dyn. index: DDS, p0180
Func. diagram: 6491
Factory setting
0000 0110 bin
0 signal
No
No
No
No
No
List Manual (LH11), 01/2016, A5E33839529
FP
6040
6040
6040
6050
6060
6030
6030
6030
6031
6030
6030
-
FP
6722
6723
6722,
6723
6722
6640