r0075
CO: Current setpoint field-generating / Id_set
Access level: 3
Can be changed: -
Unit group: 6_2
Min
- [Arms]
Description:
Display and connector output for the field-generating current setpoint (Id_set).
Dependency:
Not visible with application class: "Standard Drive Control" (SDC, p0096 = 1)
Note:
This value is irrelevant for the U/f control mode.
r0076
CO: Current actual value field-generating / Id_act
Access level: 3
Can be changed: -
Unit group: 6_2
Min
- [Arms]
Description:
Display and connector output for the field-generating current actual value (Id_act).
Dependency:
Refer to: r0029
Note:
This value is irrelevant for the U/f control mode.
The field-generating current actual value is available smoothed (r0029) and unsmoothed (r0076).
r0077
CO: Current setpoint torque-generating / Iq_set
Access level: 3
Can be changed: -
Unit group: 6_2
Min
- [Arms]
Description:
Display and connector output for the torque-generating current setpoint.
Dependency:
Not visible with application class: "Standard Drive Control" (SDC, p0096 = 1)
Note:
This value is irrelevant for the U/f control mode.
r0078
CO: Current actual value torque-generating / Iq_act
Access level: 3
Can be changed: -
Unit group: 6_2
Min
- [Arms]
Description:
Display and connector output for the torque-generating current actual value (Iq_act).
Dependency:
Refer to: r0030
Note:
This value is irrelevant for the U/f control mode.
The torque-generating current actual value is available smoothed (r0030 with 300 ms) and unsmoothed (r0078).
r0079
CO: Torque setpoint / M_set
Access level: 3
Can be changed: -
Unit group: 7_1
Min
- [Nm]
Description:
Display and connector output for the torque setpoint at the output of the speed controller.
Dependency:
Not visible with application class: "Standard Drive Control" (SDC, p0096 = 1)
SINAMICS G120 Control Units CU240B-2/CU240E-2
List Manual (LH11), 01/2016, A5E33839529
Calculated: -
Scaling: p2002
Unit selection: p0505
Max
- [Arms]
Calculated: -
Scaling: p2002
Unit selection: p0505
Max
- [Arms]
Calculated: -
Scaling: p2002
Unit selection: p0505
Max
- [Arms]
Calculated: -
Scaling: p2002
Unit selection: p0505
Max
- [Arms]
Calculated: -
Scaling: p2003
Unit selection: p0505
Max
- [Nm]
2 Parameters
2.2 List of parameters
Data type: FloatingPoint32
Dyn. index: -
Func. diagram: 6700, 6714, 6725
Factory setting
- [Arms]
Data type: FloatingPoint32
Dyn. index: -
Func. diagram: 5700, 5714, 5730,
6700, 6714, 6799
Factory setting
- [Arms]
Data type: FloatingPoint32
Dyn. index: -
Func. diagram: 6700, 6710
Factory setting
- [Arms]
Data type: FloatingPoint32
Dyn. index: -
Func. diagram: 6310, 6700, 6714,
6799
Factory setting
- [Arms]
Data type: FloatingPoint32
Dyn. index: -
Func. diagram: 6020, 6060, 6710
Factory setting
- [Nm]
47