Threshold value for
F07011:
I_act abs val [Arms]
r0068
[0]
not smoothed
n_act [rpm]
r0063
<1>
If p0610 = 12.
<2>
Only for Power Modules PM240/PM250/PM260.
1
2
Signals and monitoring functions
Motor temperature model 3
Mot temp response
1 = Activate motor temperature model 3
p0610
p0612.2 (0)
<1>
<2>
Motor temperature model 3
Only for:
Permanent-magnet synchronous motor
(PMSM) 1FK7 without encoder (p0300 =
277)
3
4
Mod T_winding [°C]
F thr image p5391 [°C]
r0632 [D]
r5399 [D]
Mod T_stator [°C]
r0631 [D]
A thr image p5390 [°C]
r5398 [D]
Mod rotor temp [°C]
r0633 [D]
r0632 – r5397
• 100 [%]
r5398 – r5397
5
fp_8019_97_58.vsd
09.12.2015
1
1
0
T
0
1
A07012
"Motor temperature model 1/3 overtemperature"
0
Mot_util therm [%]
r0034
6
7
Function diagram
G120 CU240B/E-2
V4.7.6
[8016.6]
8