2 Parameters
2.2 List of parameters
Note:
Once the Control Unit has been booted up for the first time or if the factory settings have been defined accordingly,
the parameter is defined in accordance with the power unit.
p0312[0...n]
Rated motor torque / Mot M_rated
Access level: 3
Can be changed: C(3)
Unit group: -
Min
0.00 [Nm]
Description:
Sets the rated motor torque (rating plate).
Notice:
When selecting a catalog motor (p0301), this parameter is automatically pre-assigned and is write protected.
Information in p0300 should be carefully observed when removing write protection.
r0313[0...n]
Motor pole pair number, actual (or calculated) / Mot PolePairNo act
Access level: 3
Can be changed: -
Unit group: -
Min
-
Description:
Displays the number of motor pole pairs. The value is used for internal calculations.
r0313 = 1: 2-pole motor
r0313 = 2: 4-pole motor, etc.
Dependency:
For p0314 > 0, the entered value is displayed in r0313.
For p0314 = 0, the pole pair number (r0313) is automatically calculated from the rated power (p0307), rated
frequency (p0310) and rated speed (p0311).
Refer to: p0307, p0310, p0311, p0314
Note:
For the automatic calculation, the pole pair number is set to the value of 2 if the rated speed or the rated frequency is
zero.
p0314[0...n]
Motor pole pair number / Mot pole pair No.
Access level: 3
Can be changed: C(1, 3)
Unit group: -
Min
0
Description:
Sets the motor pole pair number.
p0314 = 1: 2-pole motor
p0314 = 2: 4-pole motor, etc.
Dependency:
For p0314 = 0, the pole pair number is automatically calculated from the rated frequency (p0310) and the rated
speed (p0311) and displayed in r0313.
Notice:
If p0314 is changed during quick commissioning (p0010 = 1), the maximum speed p1082, which is also associated
with quick commissioning, is pre-assigned accordingly.
For induction motors, it is only necessary to enter the value if the rated motor slip is so high that the pole pair number
r0313, obtained when making the calculation based on the rated frequency and rated speed, is too low.
p0316[0...n]
Motor torque constant / Mot kT
Access level: 3
Can be changed: C(1, 3), U, T
Unit group: 28_1
Min
0.00 [Nm/A]
Description:
Sets the torque constant of the synchronous motor.
66
Calculated: -
Scaling: -
Unit selection: -
Max
1000000.00 [Nm]
Calculated: -
Scaling: -
Unit selection: -
Max
-
Calculated: -
Scaling: -
Unit selection: -
Max
255
Calculated: -
Scaling: -
Unit selection: p0100
Max
400.00 [Nm/A]
SINAMICS G120 Control Units CU240B-2/CU240E-2
Data type: FloatingPoint32
Dyn. index: MDS
Func. diagram: -
Factory setting
0.00 [Nm]
Data type: Unsigned16
Dyn. index: MDS
Func. diagram: 5300
Factory setting
-
Data type: Unsigned16
Dyn. index: MDS
Func. diagram: -
Factory setting
0
Data type: FloatingPoint32
Dyn. index: MDS
Func. diagram: -
Factory setting
0.00 [Nm/A]
List Manual (LH11), 01/2016, A5E33839529

Advertisement

Table of Contents
loading

Table of Contents