p9351
SI Motion SLS changeover delay time (processor 2) / SI Mtn SLS t P2
PM240
Access level: 3
PM250
Can be changed: C(95)
PM260
Unit group: -
CU240E-2_F
Min
CU240E-2_PN_F
0.00 [µs]
CU240E-2_DP_F
Description:
Sets the delay time for the SLS changeover for the function "safely limited speed" (SLS).
When transitioning from a higher to a lower safely limited velocity/speed stage, within this delay time, the "old"
velocity stage remains active.
Even if SLS is activated from the state "SLS in active", then this delay is still applied.
Dependency:
Refer to: p9551
Notice:
This parameter is overwritten by the copy function of the safety functions integrated in the drive.
Note:
SLS: Safely Limited Speed
p9356
SI Motion pulse suppression delay time (processor 2) / SI Mtn IL t_del P2
PM240
Access level: 3
PM250
Can be changed: C(95)
PM260
Unit group: -
CU240E-2_F
Min
CU240E-2_PN_F
0.00 [µs]
CU240E-2_DP_F
Description:
Sets the delay time for STOP A after STOP B / SS1.
Dependency:
Refer to: p9360, p9556
Refer to: C01701
Notice:
This parameter is overwritten by the copy function of the safety functions integrated in the drive.
Note:
The set time is rounded internally to an integer multiple of the monitoring clock cycle.
SS1: Safe Stop 1
p9358
SI Motion acceptance test mode time limit (processor 2) / SI Mtn acc t P2
PM240
Access level: 3
PM250
Can be changed: C(95)
PM260
Unit group: -
CU240E-2_F
Min
CU240E-2_PN_F
5000000.00 [µs]
CU240E-2_DP_F
Description:
Sets the maximum time for the acceptance test mode.
If the acceptance test mode takes longer than the selected time limit, then the mode is automatically terminated.
Dependency:
Refer to: p9558
Refer to: C01799
Notice:
This parameter is overwritten by the copy function of the safety functions integrated in the drive.
Note:
The set time is rounded internally to an integer multiple of the monitoring clock cycle.
p9360
SI Motion pulse suppression shutdown speed (processor 2) / SI Mtn IL n_sh P2
CU240E-2_F
Access level: 3
CU240E-2_PN_F
Can be changed: C(95)
CU240E-2_DP_F
Unit group: -
Min
10.00 [rpm]
Description:
Sets the shutdown speed for the pulse suppression.
Below this speed "standstill" is assumed and for STOP B / SS1, the pulses are suppressed (by changing to STOP A).
Dependency:
Refer to: p9356, p9560
Notice:
This parameter is overwritten by the copy function of the safety functions integrated in the drive.
SINAMICS G120 Control Units CU240B-2/CU240E-2
List Manual (LH11), 01/2016, A5E33839529
Calculated: -
Scaling: -
Unit selection: -
Max
600000000.00 [µs]
Calculated: -
Scaling: -
Unit selection: -
Max
3600000000.00 [µs]
Calculated: -
Scaling: -
Unit selection: -
Max
100000000.00 [µs]
Calculated: -
Scaling: -
Unit selection: -
Max
6000.00 [rpm]
2 Parameters
2.2 List of parameters
Data type: FloatingPoint32
Dyn. index: -
Func. diagram: 2819, 2820
Factory setting
100000.00 [µs]
Data type: FloatingPoint32
Dyn. index: -
Func. diagram: 2819
Factory setting
600000000.00 [µs]
Data type: FloatingPoint32
Dyn. index: -
Func. diagram: -
Factory setting
40000000.00 [µs]
Data type: FloatingPoint32
Dyn. index: -
Func. diagram: -
Factory setting
10.00 [rpm]