2 Parameters
2.2 List of parameters
r1583
Flux setpoint smoothed / Flux setp smooth
Access level: 4
Can be changed: -
Unit group: -
Min
- [%]
Description:
Displays the smoothed flux setpoint.
The value is referred to the rated motor flux.
Dependency:
Not visible with application class: "Standard Drive Control" (SDC, p0096 = 1)
p1584[0...n]
Field weakening operation flux setpoint smoothing time / Field weak T_smth
Access level: 4
Can be changed: U, T
Unit group: -
Min
0 [ms]
Description:
Sets the smoothing time for the flux setpoint in the field-weakening range
Recommendation:
Smoothing should be especially used if there is no regenerative feedback into the line supply. This means that the
DC link voltage can quickly increase in regenerative operation
Dependency:
Not visible with application class: "Standard Drive Control" (SDC, p0096 = 1), "Dynamic Drive Control" (DDC, p0096
= 2)
Note:
Only the flux setpoint rise is smoothed
p1586[0...n]
Field weakening characteristic scaling / Field weak scal
Access level: 4
Can be changed: U, T
Unit group: -
Min
80.0 [%]
Description:
Sets the scaling of the pre-control characteristic for the start of field weakening.
For values above 100 % and for partial load situations, the field weakening starts at higher speeds.
Dependency:
Not visible with application class: "Standard Drive Control" (SDC, p0096 = 1), "Dynamic Drive Control" (DDC, p0096
= 2)
Note:
If the start of field weakening is shifted to lower speeds, then the voltage reserve is increased for partial load
situations.
If the start of field weakening is shifted to higher speeds, the voltage reserve is appropriately reduced so that for fast
load changes, it can be expected that this will have a negative impact on the dynamic performance.
r1589
Field-weakening current pre-control value / I_FieldWeak prectr
Access level: 4
Can be changed: -
Unit group: 6_2
Min
- [Arms]
Description:
Displays the pre-control value for the field weakening current.
Dependency:
Not visible with application class: "Standard Drive Control" (SDC, p0096 = 1)
236
Calculated: -
Scaling: PERCENT
Unit selection: -
Max
- [%]
Calculated: p0340 = 1,3
Scaling: -
Unit selection: -
Max
20000 [ms]
Calculated: -
Scaling: -
Unit selection: -
Max
120.0 [%]
Calculated: -
Scaling: p2002
Unit selection: p0505
Max
- [Arms]
SINAMICS G120 Control Units CU240B-2/CU240E-2
Data type: FloatingPoint32
Dyn. index: -
Func. diagram: 6722, 6723, 6724
Factory setting
- [%]
Data type: FloatingPoint32
Dyn. index: DDS, p0180
Func. diagram: 6722
Factory setting
0 [ms]
Data type: FloatingPoint32
Dyn. index: DDS, p0180
Func. diagram: -
Factory setting
100.0 [%]
Data type: FloatingPoint32
Dyn. index: -
Func. diagram: 6724
Factory setting
- [Arms]
List Manual (LH11), 01/2016, A5E33839529