Siemens SINAMICS G120 List Manual page 511

Hide thumbs Also See for SINAMICS G120:
Table of Contents

Advertisement

p20285
DIF 0 differentiating time constant in ms / DIF 0 T_diff ms
Access level: 3
Can be changed: T
Unit group: -
Min
0.00
Description:
Sets the differentiating time constant Td in milliseconds of instance DIF 0 of the differentiating element.
r20286
CO: DIF 0 output Y / DIF 0 output Y
Access level: 3
Can be changed: -
Unit group: -
Min
-
Description:
Display parameter for output quantity Y of instance DIF 0 of the differentiating element.
p20287
DIF 0 run-time group / DIF 0 RTG
Access level: 3
Can be changed: T
Unit group: -
Min
5
Description:
Setting parameter for the run-time group in which instance DIF 0 of the differentiating element is to be called.
Value:
5:
6:
9999: Do not calculate
p20288
DIF 0 run sequence / DIF 0 RunSeq
Access level: 3
Can be changed: T
Unit group: -
Min
0
Description:
Setting parameter for the run sequence of instance DIF 0 within the run-time group set in p20287.
Note:
The function blocks with a lower run sequence value are calculated before function blocks with a higher run
sequence value.
p20300
BI: NOT 4 input I / NOT 4 input I
Access level: 3
Can be changed: T
Unit group: -
Min
-
Description:
Sets the signal source of input quantity I of instance NOT 4 of the inverter.
r20301
BO: NOT 4 inverted output / NOT 4 inv output
Access level: 3
Can be changed: -
Unit group: -
Min
-
Description:
Display parameter for the inverted output of instance NOT 4 of the inverter.
SINAMICS G120 Control Units CU240B-2/CU240E-2
List Manual (LH11), 01/2016, A5E33839529
Run-time group 5
Run-time group 6
Calculated: -
Scaling: -
Unit selection: -
Max
340.28235E36
Calculated: -
Scaling: PERCENT
Unit selection: -
Max
-
Calculated: -
Scaling: -
Unit selection: -
Max
9999
Calculated: -
Scaling: -
Unit selection: -
Max
32000
Calculated: -
Scaling: -
Unit selection: -
Max
-
Calculated: -
Scaling: -
Unit selection: -
Max
-
2 Parameters
2.2 List of parameters
Data type: FloatingPoint32
Dyn. index: -
Func. diagram: 7264
Factory setting
0.00
Data type: FloatingPoint32
Dyn. index: -
Func. diagram: 7264
Factory setting
-
Data type: Integer16
Dyn. index: -
Func. diagram: 7264
Factory setting
9999
Data type: Unsigned16
Dyn. index: -
Func. diagram: 7264
Factory setting
750
Data type: U32 / Binary
Dyn. index: -
Func. diagram: 7216
Factory setting
0
Data type: Unsigned32
Dyn. index: -
Func. diagram: 7216
Factory setting
-
511