Siemens SINAMICS G120 List Manual page 404

Hide thumbs Also See for SINAMICS G120:
Table of Contents

Advertisement

2 Parameters
2.2 List of parameters
Dependency:
Refer to: p9484, r9486
Note:
The signal source to be searched is set in p9484 (BICO-coded).
The search result is contained in r9482 and r9483 and is specified by the count (r9485) and the first index (r9486).
r9486
BICO interconnections signal source search first index / BICO S_src srchIdx
Access level: 3
Can be changed: -
Unit group: -
Min
-
Description:
Displays the first index of the signal source being searched for.
The signal source to be searched for is set in p9484 (BICO-coded) and the search result is specified using the
number (r9485) and the first index (r9486).
Dependency:
Refer to: p9484, r9485
Note:
The signal source to be searched is set in p9484 (BICO-coded).
The search result is contained in r9482 and r9483 and is specified by the count (r9485) and the first index (r9486).
p9501
SI Motion enable safety functions (processor 1) / SI Mtn enable P1
PM240
Access level: 3
PM250
Can be changed: C(95)
PM260
Unit group: -
CU240E-2_F
Min
-
Description:
Sets the enable signals for the safe motion monitoring.
Bit field:
Bit
00
17
Dependency:
Refer to: F01682, F01683
Note:
For bit 30 = 1, PROFIsafe telegram 900 must be configured in the F host.
A change only becomes effective after a POWER ON.
F-DI: Failsafe Digital Input
SDI: Safe Direction (safe motion direction)
SLS: Safely Limited Speed
SSM: Safe Speed Monitor (safety-relevant feedback signal from the velocity monitoring)
p9501
SI Motion enable safety functions (processor 1) / SI Mtn enable P1
PM240
Access level: 3
PM250
Can be changed: C(95)
PM260
Unit group: -
CU240E-2_PN_F
Min
CU240E-2_DP_F
-
Description:
Sets the enable signals for the safe motion monitoring.
Bit field:
Bit
00
16
17
30
Dependency:
Refer to: F01682, F01683
404
Signal name
Enable SI Motion
Enable SDI
Signal name
Enable SI Motion
Enable SSM hysteresis and filtering
Enable SDI
Enable F-DI in PROFIsafe telegram
Calculated: -
Scaling: -
Unit selection: -
Max
-
Calculated: -
Scaling: -
Unit selection: -
Max
-
1 signal
Enable
Enable
Calculated: -
Scaling: -
Unit selection: -
Max
-
1 signal
Enable
Enable
Enable
Enable
SINAMICS G120 Control Units CU240B-2/CU240E-2
Data type: Unsigned16
Dyn. index: -
Func. diagram: -
Factory setting
-
Data type: Unsigned32
Dyn. index: -
Func. diagram: -
Factory setting
0000 0000 0000 0000 0000 0000 0000
0000 bin
0 signal
Inhibit
Inhibit
Data type: Unsigned32
Dyn. index: -
Func. diagram: -
Factory setting
0000 0000 0000 0000 0000 0000 0000
0000 bin
0 signal
Inhibit
Inhibit
Inhibit
Inhibit
List Manual (LH11), 01/2016, A5E33839529
FP
-
2824
FP
-
2823
2824
-

Advertisement

Table of Contents
loading

Table of Contents