2 Parameters
2.2 List of parameters
p20246
PT1 0 smoothing time constant in ms / PT1 0 T_smooth ms
Access level: 3
Can be changed: T
Unit group: -
Min
0.00
Description:
Sets the smoothing time constant T in milliseconds of instance PT1 0 of the smoothing element.
r20247
CO: PT1 0 output Y / PT1 0 output Y
Access level: 3
Can be changed: -
Unit group: -
Min
-
Description:
Display parameter for the smoothed output quantity Y of instance PT1 0 of the smoothing element.
p20248
PT1 0 run-time group / PT1 0 RTG
Access level: 3
Can be changed: T
Unit group: -
Min
5
Description:
Setting parameter for the run-time group in which instance PT1 0 of the smoothing element is to be called.
Value:
5:
6:
9999: Do not calculate
p20249
PT1 0 run sequence / PT1 0 RunSeq
Access level: 3
Can be changed: T
Unit group: -
Min
0
Description:
Setting parameter for the run sequence of instance PT1 0 within the run-time group set in p20248.
Note:
The function blocks with a lower run sequence value are calculated before function blocks with a higher run
sequence value.
p20250[0...1]
CI: PT1 1 inputs / PT1 1 inputs
Access level: 3
Can be changed: T
Unit group: -
Min
-
Description:
Sets the signal source of input quantity X and of setting value SV of instance PT1 1 of the smoothing element.
Index:
[0] = Input X
[1] = Setting value SV
504
Run-time group 5
Run-time group 6
Calculated: -
Scaling: -
Unit selection: -
Max
340.28235E36
Calculated: -
Scaling: PERCENT
Unit selection: -
Max
-
Calculated: -
Scaling: -
Unit selection: -
Max
9999
Calculated: -
Scaling: -
Unit selection: -
Max
32000
Calculated: -
Scaling: PERCENT
Unit selection: -
Max
-
SINAMICS G120 Control Units CU240B-2/CU240E-2
Data type: FloatingPoint32
Dyn. index: -
Func. diagram: 7262
Factory setting
0.00
Data type: FloatingPoint32
Dyn. index: -
Func. diagram: 7262
Factory setting
-
Data type: Integer16
Dyn. index: -
Func. diagram: 7262
Factory setting
9999
Data type: Unsigned16
Dyn. index: -
Func. diagram: 7262
Factory setting
670
Data type: U32 / FloatingPoint32
Dyn. index: -
Func. diagram: 7262
Factory setting
0