r20145
BO: MFP 1 output Q / MFP 1 output Q
Access level: 3
Can be changed: -
Unit group: -
Min
-
Description:
Display parameter for output pulse Q of instance MFP 1 of the pulse generator.
p20146
MFP 1 run-time group / MFP 1 RTG
Access level: 3
Can be changed: T
Unit group: -
Min
5
Description:
Setting parameter for the run-time group in which the instance MFP 1 of the pulse generator is to be called.
Value:
5:
6:
9999: Do not calculate
p20147
MFP 1 run sequence / MFP 1 RunSeq
Access level: 3
Can be changed: T
Unit group: -
Min
0
Description:
Setting parameter for the run sequence of instance MFP 1 within the run-time group set in p20146.
Note:
The function blocks with a lower run sequence value are calculated before function blocks with a higher run
sequence value.
p20148
BI: PCL 0 input pulse I / PCL 0 inp_pulse I
Access level: 3
Can be changed: T
Unit group: -
Min
-
Description:
Sets the signal source for the input pulse I of instance PCL 0 of the pulse shortener.
p20149
PCL 0 pulse duration in ms / PCL 0 pulse_dur ms
Access level: 3
Can be changed: T
Unit group: -
Min
0.00
Description:
Setting parameter for pulse duration T in milliseconds of instance PCL 0 of the pulse shortener.
r20150
BO: PCL 0 output Q / PCL 0 output Q
Access level: 3
Can be changed: -
Unit group: -
Min
-
Description:
Display parameter for output pulse Q of instance PCL 0 of the pulse shortener.
SINAMICS G120 Control Units CU240B-2/CU240E-2
List Manual (LH11), 01/2016, A5E33839529
Run-time group 5
Run-time group 6
Calculated: -
Scaling: -
Unit selection: -
Max
-
Calculated: -
Scaling: -
Unit selection: -
Max
9999
Calculated: -
Scaling: -
Unit selection: -
Max
32000
Calculated: -
Scaling: -
Unit selection: -
Max
-
Calculated: -
Scaling: -
Unit selection: -
Max
5400000.00
Calculated: -
Scaling: -
Unit selection: -
Max
-
2 Parameters
2.2 List of parameters
Data type: Unsigned32
Dyn. index: -
Func. diagram: 7230
Factory setting
-
Data type: Integer16
Dyn. index: -
Func. diagram: 7230
Factory setting
9999
Data type: Unsigned16
Dyn. index: -
Func. diagram: 7230
Factory setting
380
Data type: U32 / Binary
Dyn. index: -
Func. diagram: 7230
Factory setting
0
Data type: FloatingPoint32
Dyn. index: -
Func. diagram: 7230
Factory setting
0.00
Data type: Unsigned32
Dyn. index: -
Func. diagram: 7230
Factory setting
-
485