p20348
PDF 2 run sequence / PDF 2 RunSeq
Access level: 3
Can be changed: T
Unit group: -
Min
0
Description:
Setting parameter for the run sequence of instance PDE 2 within the run-time group set in p20347.
Note:
The function blocks with a lower run sequence value are calculated before function blocks with a higher run
sequence value.
p20349
BI: PDF 3 input pulse I / PDF 3 inp_pulse I
Access level: 3
Can be changed: T
Unit group: -
Min
-
Description:
Sets the signal source for the input pulse I of instance PDF 3 of the breaking delay device.
p20350
PDF 3 pulse extension time in ms / PDF 3 t_ext ms
Access level: 3
Can be changed: T
Unit group: -
Min
0.00
Description:
Setting parameter for pulse extension time T in milliseconds of instance PDF 3 of the breaking delay device.
r20351
BO: PDF 3 output Q / PDF 3 output Q
Access level: 3
Can be changed: -
Unit group: -
Min
-
Description:
Display parameter for output pulse Q of instance PDF 3 of the breaking delay device.
p20352
PDF 3 run-time group / PDF 3 RTG
Access level: 3
Can be changed: T
Unit group: -
Min
5
Description:
Setting parameter for the run-time group in which the instance PDF 3 of the breaking delay device is to be called.
Value:
5:
6:
9999: Do not calculate
p20353
PDF 3 run sequence / PDF 3 RunSeq
Access level: 3
Can be changed: T
Unit group: -
Min
0
Description:
Setting parameter for the run sequence of instance PDE 3 within the run-time group set in p20352.
SINAMICS G120 Control Units CU240B-2/CU240E-2
List Manual (LH11), 01/2016, A5E33839529
Run-time group 5
Run-time group 6
Calculated: -
Scaling: -
Unit selection: -
Max
32000
Calculated: -
Scaling: -
Unit selection: -
Max
-
Calculated: -
Scaling: -
Unit selection: -
Max
5400000.00
Calculated: -
Scaling: -
Unit selection: -
Max
-
Calculated: -
Scaling: -
Unit selection: -
Max
9999
Calculated: -
Scaling: -
Unit selection: -
Max
32000
2 Parameters
2.2 List of parameters
Data type: Unsigned16
Dyn. index: -
Func. diagram: 7233
Factory setting
920
Data type: U32 / Binary
Dyn. index: -
Func. diagram: 7233
Factory setting
0
Data type: FloatingPoint32
Dyn. index: -
Func. diagram: 7233
Factory setting
0.00
Data type: Unsigned32
Dyn. index: -
Func. diagram: 7233
Factory setting
-
Data type: Integer16
Dyn. index: -
Func. diagram: 7233
Factory setting
9999
Data type: Unsigned16
Dyn. index: -
Func. diagram: 7233
Factory setting
930
521