Siemens SINAMICS G120 List Manual page 622

Hide thumbs Also See for SINAMICS G120:
Table of Contents

Advertisement

From speed signals [8010.8]
From speed signals
From speed signals [8011.8]
From speed signals [8011.8]
From speed signals [8012.5]
<1>
n_act = smoothed speed actual value r2169 [8010.2].
1
2
Internal control/status words
Status word, monitoring functions 3 (r2199)
PROFIdrive-Bit
Bit No.
Status word, monitoring functions 3 (r2199)
0
1 = |n_act| < speed threshold value 3 (p2161)
1 = f or n comparison value reached or exceeded (p2141)
[8010.8]
1
Reserved
2
3
Reserved
4
1 = Speed setpoint - actual value deviation within tolerance t_on
5
1 = Ramp-up/ramp-down completed
Reserved
6
Reserved
7
8
Reserved
9
Reserved
10
Reserved
1 = Torque utilization < torque threshold value 2 (p2194)
11
Reserved
12
Reserved
13
14
Reserved
15
Reserved
3
4
<1>
r2199.0
r2199.1
r2199.4
r2199.5
r2199.11
5
6
Function diagram
fp_2537_97_63.vsd
G120 CU240B/E-2
09.12.2015
V4.7.6
ZSW monitor 3
r2199
r2199
[8012.1], [8023.1]
7
8
- 2537 -