Siemens SINAMICS G120 List Manual page 322

Hide thumbs Also See for SINAMICS G120:
Table of Contents

Advertisement

2 Parameters
2.2 List of parameters
04
05
11
Note:
For bit 00:
The speed threshold value 3 is set in p2161.
For bit 01:
The comparison value is set in p2141. We recommend setting the hysteresis (p2142) for canceling the bit to a value
lower than that in p2141. Otherwise, the bit is not reset.
For bit 11:
The torque threshold value 2 is set in p2194.
p2200[0...n]
BI: Technology controller enable / Tec_ctrl enable
Access level: 2
Can be changed: T
Unit group: -
Min
-
Description:
Sets the signal source to switch in/switch out the technology controller.
The technology controller is switched in with a 1 signal.
p2201[0...n]
CO: Technology controller fixed value 1 / Tec_ctrl fix val1
Access level: 2
Can be changed: U, T
Unit group: 9_1
Min
-200.00 [%]
Description:
Sets the value for fixed value 1 of the technology controller.
Dependency:
Refer to: p2220, p2221, p2222, p2223, r2224, r2229
Notice:
A BICO interconnection to a parameter that belongs to a drive data set always acts on the effective data set.
p2202[0...n]
CO: Technology controller fixed value 2 / Tec_ctr fix val 2
Access level: 2
Can be changed: U, T
Unit group: 9_1
Min
-200.00 [%]
Description:
Sets the value for fixed value 2 of the technology controller.
Dependency:
Refer to: p2220, p2221, p2222, p2223, r2224, r2229
Notice:
A BICO interconnection to a parameter that belongs to a drive data set always acts on the effective data set.
p2203[0...n]
CO: Technology controller fixed value 3 / Tec_ctr fix val 3
Access level: 2
Can be changed: U, T
Unit group: 9_1
Min
-200.00 [%]
Description:
Sets the value for fixed value 3 of the technology controller.
Dependency:
Refer to: p2220, p2221, p2222, p2223, r2224, r2229
Notice:
A BICO interconnection to a parameter that belongs to a drive data set always acts on the effective data set.
322
Speed setp - act val deviation in tolerance
t_on
Ramp-up/ramp-down completed
Torque utilization < torque threshold value 2 Yes
Yes
Yes
Calculated: -
Scaling: -
Unit selection: -
Max
-
Calculated: -
Scaling: PERCENT
Unit selection: p0595
Max
200.00 [%]
Calculated: -
Scaling: PERCENT
Unit selection: p0595
Max
200.00 [%]
Calculated: -
Scaling: PERCENT
Unit selection: p0595
Max
200.00 [%]
SINAMICS G120 Control Units CU240B-2/CU240E-2
No
No
No
Data type: U32 / Binary
Dyn. index: CDS, p0170
Func. diagram: 7958
Factory setting
0
Data type: FloatingPoint32
Dyn. index: DDS, p0180
Func. diagram: 7950, 7951
Factory setting
10.00 [%]
Data type: FloatingPoint32
Dyn. index: DDS, p0180
Func. diagram: 7950, 7951
Factory setting
20.00 [%]
Data type: FloatingPoint32
Dyn. index: DDS, p0180
Func. diagram: 7950, 7951
Factory setting
30.00 [%]
List Manual (LH11), 01/2016, A5E33839529