2 Parameters
2.2 List of parameters
r2136[0...63]
Fault time removed in days / t_flt resolv days
Access level: 3
Can be changed: -
Unit group: -
Min
-
Description:
Displays the system runtime in days when the fault was removed.
Dependency:
Refer to: r0945, r0947, r0948, r0949, r2109, r2130, r2133
Notice:
The time comprises r2136 (days) and r2109 (milliseconds).
Note:
The buffer parameters are cyclically updated in the background (refer to status signal in r2139).
r2138.7...15
CO/BO: Control word faults/alarms / STW fault/alarm
Access level: 2
Can be changed: -
Unit group: -
Min
-
Description:
Display and BICO output for the control word of faults and alarms.
Bit field:
Bit
07
10
11
12
13
14
15
Dependency:
Refer to: p2103, p2104, p2105, p2106, p2107, p2108, p2112, p2116, p2117, p3110, p3111, p3112
r2139.0...15
CO/BO: Status word faults/alarms 1 / ZSW fault/alarm 1
Access level: 2
Can be changed: -
Unit group: -
Min
-
Description:
Display and BICO output for status word 1 of faults and alarms.
Bit field:
Bit
00
01
03
06
07
08
11
12
13
14
15
Note:
For bit 03, 07:
These bits are set if at least one fault/alarm occurs. Data is entered into the fault/alarm buffer with delay. This is the
reason that the fault/alarm buffer should only be read if, after "fault present" or "alarm present" has occurred, a
change in the buffer was also detected (r0944, r9744, r2121).
For bit 06, 08:
These status bits are used for internal diagnostic purposes only.
For bit 11, 12:
These status bits are used for the classification of internal alarm classes and are intended for diagnostic purposes
only on certain automation systems with integrated SINAMICS functionality.
306
Signal name
Acknowledge fault
External alarm 1 (A07850) effective
External alarm 2 (A07851) effective
External alarm 3 (A07852) effective
External fault 1 (F07860) effective
External fault 2 (F07861) effective
External fault 3 (F07862) effective
Signal name
Being acknowledged
Acknowledgment required
Fault present
Internal message 1 present
Alarm present
Internal message 2 present
Alarm class bit 0
Alarm class bit 1
Maintenance required
Maintenance urgently required
Fault gone/can be acknowledged
Calculated: -
Scaling: -
Unit selection: -
Max
-
Calculated: -
Scaling: -
Unit selection: -
Max
-
1 signal
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Calculated: -
Scaling: -
Unit selection: -
Max
-
1 signal
Yes
Yes
Yes
Yes
Yes
Yes
High
High
Yes
Yes
Yes
SINAMICS G120 Control Units CU240B-2/CU240E-2
Data type: Unsigned16
Dyn. index: -
Func. diagram: 8060
Factory setting
-
Data type: Unsigned16
Dyn. index: -
Func. diagram: 2546
Factory setting
-
0 signal
No
No
No
No
No
No
No
Data type: Unsigned16
Dyn. index: -
Func. diagram: 2548
Factory setting
-
0 signal
No
No
No
No
No
No
Low
Low
No
No
No
List Manual (LH11), 01/2016, A5E33839529
FP
8060
8065
8065
8065
8060
8060
8060
FP
-
-
8060
-
8065
-
-
-
-
-
-

Advertisement

Table of Contents
loading

Table of Contents