Siemens SINAMICS G120 List Manual page 214

Hide thumbs Also See for SINAMICS G120:
Table of Contents

Advertisement

2 Parameters
2.2 List of parameters
11
12
13
14
15
17
23
24
25
26
27
Dependency:
Not visible with application class: "Standard Drive Control" (SDC, p0096 = 1)
r1408.0...14
CO/BO: Status word current controller / ZSW I_ctrl
Access level: 4
Can be changed: -
Unit group: -
Min
-
Description:
Display and BICO output for the status word of the current controller.
Bit field:
Bit
00
01
03
10
12
13
14
Dependency:
Not visible with application class: "Standard Drive Control" (SDC, p0096 = 1)
p1416[0...n]
Speed setpoint filter 1 time constant / n_set_filt 1 T
Access level: 4
Can be changed: U, T
Unit group: -
Min
0.00 [ms]
Description:
Sets the time constant for the speed setpoint filter 1 (PT1).
Dependency:
Not visible with application class: "Standard Drive Control" (SDC, p0096 = 1)
r1438
CO: Speed controller speed setpoint / n_ctrl n_set
Access level: 3
Can be changed: -
Unit group: 3_1
Min
- [rpm]
Description:
Display and connector output of the speed setpoint after setpoint limiting for the P component of the speed controller.
For U/f operation, the value that is displayed is of no relevance.
Dependency:
Not visible with application class: "Standard Drive Control" (SDC, p0096 = 1)
Refer to: r1439
Note:
In the standard state (the reference model is de-activated), r1438 = r1439.
214
Speed setpoint limited
Ramp-function generator set
Encoderless operation due to a fault
I/f control active
Torque limit reached (without pre-control)
Speed limiting control active
Acceleration model activated
Moment of inertia estimator active
Load estimate active
Moment of inertia estimator stabilized
Accelerated moment of inertia estimator
active
Signal name
Current controller act
Id control I component limiting
Voltage limiting
Speed adaptation limiting
Motor stalled
Separately excited synchronous motor is
excited
Current model SESM magnetizing excit.
current limited to zero
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Calculated: -
Scaling: -
Unit selection: -
Max
-
1 signal
Active
Active
Active
Active
Yes
Yes
Yes
Calculated: -
Scaling: -
Unit selection: -
Max
5000.00 [ms]
Calculated: -
Scaling: p2000
Unit selection: p0505
Max
- [rpm]
SINAMICS G120 Control Units CU240B-2/CU240E-2
No
No
No
No
No
No
No
No
No
No
No
Data type: Unsigned16
Dyn. index: -
Func. diagram: 2530
Factory setting
-
0 signal
Not active
Not active
Not active
Not active
No
No
No
Data type: FloatingPoint32
Dyn. index: DDS, p0180
Func. diagram: 6020, 6030
Factory setting
0.00 [ms]
Data type: FloatingPoint32
Dyn. index: -
Func. diagram: 3001, 6020, 6031
Factory setting
- [rpm]
List Manual (LH11), 01/2016, A5E33839529
6030
-
-
-
6060
6640
-
-
-
-
-
FP
-
6714
6714
-
-
-
-