2 Parameters
2.2 List of parameters
Value:
0:
12:
13:
15:
172:
Dependency:
Refer to: p9358, p9370
Refer to: C01799
p9381
SI Motion brake ramp reference value (processor 2) / SI Mtn ramp ref P2
CU240E-2_F
Access level: 3
CU240E-2_PN_F
Can be changed: C(95)
CU240E-2_DP_F
Unit group: -
Min
600.0000 [rpm]
Description:
Sets the reference value to define the brake ramp.
The rate of rise of the brake ramp depends upon p9381 (reference value) and p9383 (monitoring time).
Dependency:
Refer to: p9382, p9383
Notice:
This parameter is overwritten by the copy function of the safety functions integrated in the drive.
p9382
SI Motion brake ramp delay time (processor 2) / SI Mtn rp t_del P2
PM240
Access level: 3
PM250
Can be changed: C(95)
PM260
Unit group: -
CU240E-2_F
Min
CU240E-2_PN_F
10000.00 [µs]
CU240E-2_DP_F
Description:
Sets the delay time for monitoring the brake ramp.
Monitoring of the brake ramp starts once the delay time has elapsed.
Dependency:
Refer to: p9381, p9383
Notice:
This parameter is overwritten by the copy function of the safety functions integrated in the drive.
Note:
The set time is rounded internally to an integer multiple of the monitoring clock cycle.
Internally, the set time is limited downwards to 2 safety monitoring clock cycles (2 * 12 ms).
p9383
SI Motion brake ramp monitoring time (processor 2) / SI Mtn rp t_mon P2
PM240
Access level: 3
PM250
Can be changed: C(95)
PM260
Unit group: -
CU240E-2_F
Min
CU240E-2_PN_F
500.00 [ms]
CU240E-2_DP_F
Description:
Sets the monitoring time to define the brake ramp.
The rate of rise of the brake ramp depends upon p9381 (reference value) and p9383 (monitoring time).
Dependency:
Refer to: p9381, p9382
Notice:
This parameter is overwritten by the copy function of the safety functions integrated in the drive.
Note:
The set time is rounded internally to an integer multiple of the monitoring clock cycle.
p9385
SI Motion actual value sensing sensorless fault tolerance (MM) / ActVal sl tol MM
PM240
Access level: 3
PM250
Can be changed: C(95)
PM260
Unit group: -
CU240E-2_F
Min
CU240E-2_PN_F
-1
CU240E-2_DP_F
Description:
Sets the tolerance of the plausibility monitoring of the current and voltage angle.
398
[00 hex] Acc_mode inactive
[0C hex] Acc_mode not possible due to POWER ON fault
[0D hex] Acc_mode not possible due to incorrect ID in p9370
[0F hex] Acc_mode not possible due to expired Acc_timer
[AC hex] Acc_mode active
Calculated: -
Scaling: -
Unit selection: -
Max
240000.0000 [rpm]
Calculated: -
Scaling: -
Unit selection: -
Max
99000000.00 [µs]
Calculated: -
Scaling: -
Unit selection: -
Max
3600000.00 [ms]
Calculated: -
Scaling: -
Unit selection: -
Max
4
SINAMICS G120 Control Units CU240B-2/CU240E-2
Data type: FloatingPoint32
Dyn. index: -
Func. diagram: -
Factory setting
1500.0000 [rpm]
Data type: FloatingPoint32
Dyn. index: -
Func. diagram: -
Factory setting
250000.00 [µs]
Data type: FloatingPoint32
Dyn. index: -
Func. diagram: -
Factory setting
10000.00 [ms]
Data type: Integer32
Dyn. index: -
Func. diagram: -
Factory setting
-1
List Manual (LH11), 01/2016, A5E33839529