2 Parameters
2.2 List of parameters
r0382[0...n]
Motor magnetizing inductance transformed / Mot L_magn transf
Access level: 4
Can be changed: -
Unit group: -
Min
- [mH]
Description:
Displays the magnetizing inductance of the motor.
Note:
The parameter is not used for synchronous motors (p0300 = 2xx).
r0384[0...n]
Motor rotor time constant / damping time constant d axis / Mot T_rotor/T_Dd
Access level: 3
Can be changed: -
Unit group: -
Min
- [ms]
Description:
Displays the rotor time constant.
Note:
The parameter is not used for synchronous motors.
The value is calculated from the total of the inductances on the rotor side (p0358, p0360) divided by the rotor
resistance (p0354). The temperature adaptation of the rotor resistance for induction motors is not taken into account.
r0386[0...n]
Motor stator leakage time constant / Mot T_stator leak
Access level: 4
Can be changed: -
Unit group: -
Min
- [ms]
Description:
Displays the stator leakage time constant.
Note:
The value is calculated from the total of all leakage inductances (p0233, p0356, p0358) divided by the total of all
motor resistances (p0350, p0352, p0354). The temperature adaptation of the resistances is not taken into account.
r0394[0...n]
Rated motor power / Mot P_rated
Access level: 3
Can be changed: -
Unit group: 14_6
Min
- [kW]
Description:
Displays the rated motor power.
Note:
The parameter displays p0307. For p0307 = 0, r0394 is calculated from p0304 and p0305 (only for induction motors).
Depending on the actual motor type, deviations can occur from the actual rated motor power.
r0395[0...n]
Actual stator resistance / R_stator act
Access level: 3
Can be changed: -
Unit group: -
Min
- [ohm]
Description:
Displays the actual stator resistance (phase value).
The parameter value also contains the temperature-independent cable resistance.
Dependency:
In the case of induction motors the parameter is also affected by the motor temperature model.
Refer to: p0350, p0352, p0620
Note:
In each case, only the stator resistance of the active Motor Data Set is included with the stator temperature of the
thermal motor model.
80
Calculated: -
Scaling: -
Unit selection: -
Max
- [mH]
Calculated: -
Scaling: -
Unit selection: -
Max
- [ms]
Calculated: -
Scaling: -
Unit selection: -
Max
- [ms]
Calculated: -
Scaling: -
Unit selection: p0100
Max
- [kW]
Calculated: -
Scaling: -
Unit selection: -
Max
- [ohm]
SINAMICS G120 Control Units CU240B-2/CU240E-2
Data type: FloatingPoint32
Dyn. index: MDS
Func. diagram: -
Factory setting
- [mH]
Data type: FloatingPoint32
Dyn. index: MDS
Func. diagram: 6722
Factory setting
- [ms]
Data type: FloatingPoint32
Dyn. index: MDS
Func. diagram: -
Factory setting
- [ms]
Data type: FloatingPoint32
Dyn. index: MDS
Func. diagram: -
Factory setting
- [kW]
Data type: FloatingPoint32
Dyn. index: MDS
Func. diagram: -
Factory setting
- [ohm]
List Manual (LH11), 01/2016, A5E33839529