p1010[0...n]
CO: Fixed speed setpoint 10 / n_set_fixed 10
Access level: 2
Can be changed: U, T
Unit group: 3_1
Min
-210000.000 [rpm]
Description:
Setting and connector output for fixed speed setpoint 10.
Dependency:
Refer to: p1020, p1021, p1022, p1023, r1024, r1197
Notice:
A BICO interconnection to a parameter that belongs to a drive data set always acts on the effective data set.
p1011[0...n]
CO: Fixed speed setpoint 11 / n_set_fixed 11
Access level: 2
Can be changed: U, T
Unit group: 3_1
Min
-210000.000 [rpm]
Description:
Setting and connector output for fixed speed setpoint 11.
Dependency:
Refer to: p1020, p1021, p1022, p1023, r1024, r1197
Notice:
A BICO interconnection to a parameter that belongs to a drive data set always acts on the effective data set.
p1012[0...n]
CO: Fixed speed setpoint 12 / n_set_fixed 12
Access level: 2
Can be changed: U, T
Unit group: 3_1
Min
-210000.000 [rpm]
Description:
Setting and connector output for fixed speed setpoint 12.
Dependency:
Refer to: p1020, p1021, p1022, p1023, r1024, r1197
Notice:
A BICO interconnection to a parameter that belongs to a drive data set always acts on the effective data set.
p1013[0...n]
CO: Fixed speed setpoint 13 / n_set_fixed 13
Access level: 2
Can be changed: U, T
Unit group: 3_1
Min
-210000.000 [rpm]
Description:
Setting and connector output for fixed speed setpoint 13.
Dependency:
Refer to: p1020, p1021, p1022, p1023, r1024, r1197
Notice:
A BICO interconnection to a parameter that belongs to a drive data set always acts on the effective data set.
p1014[0...n]
CO: Fixed speed setpoint 14 / n_set_fixed 14
Access level: 2
Can be changed: U, T
Unit group: 3_1
Min
-210000.000 [rpm]
Description:
Setting and connector output for fixed speed setpoint 14.
Dependency:
Refer to: p1020, p1021, p1022, p1023, r1024, r1197
Notice:
A BICO interconnection to a parameter that belongs to a drive data set always acts on the effective data set.
SINAMICS G120 Control Units CU240B-2/CU240E-2
List Manual (LH11), 01/2016, A5E33839529
Calculated: -
Scaling: p2000
Unit selection: p0505
Max
210000.000 [rpm]
Calculated: -
Scaling: p2000
Unit selection: p0505
Max
210000.000 [rpm]
Calculated: -
Scaling: p2000
Unit selection: p0505
Max
210000.000 [rpm]
Calculated: -
Scaling: p2000
Unit selection: p0505
Max
210000.000 [rpm]
Calculated: -
Scaling: p2000
Unit selection: p0505
Max
210000.000 [rpm]
2 Parameters
2.2 List of parameters
Data type: FloatingPoint32
Dyn. index: DDS, p0180
Func. diagram: 3010
Factory setting
0.000 [rpm]
Data type: FloatingPoint32
Dyn. index: DDS, p0180
Func. diagram: 3010
Factory setting
0.000 [rpm]
Data type: FloatingPoint32
Dyn. index: DDS, p0180
Func. diagram: 3010
Factory setting
0.000 [rpm]
Data type: FloatingPoint32
Dyn. index: DDS, p0180
Func. diagram: 3010
Factory setting
0.000 [rpm]
Data type: FloatingPoint32
Dyn. index: DDS, p0180
Func. diagram: 3010
Factory setting
0.000 [rpm]
149