Siemens SINAMICS G120 List Manual page 623

Hide thumbs Also See for SINAMICS G120:
Table of Contents

Advertisement

1st acknowledge
p2103 [C]
(2090.7)
2nd acknowledge
p2104 [C]
(722.2)
3rd acknowledge
p2105 [C]
(0)
Pulse generator
External fault 3
Ext fault 3 t_on
p2108 [C]
0 ... 1000 [ms]
p3110 (0)
(1)
Ext fault 3 enab
p3111 [C]
T
0
(1)
Ext flt 3 enab neg
p3112 [C]
(0)
1
2
Internal control/status words
Control word, faults/alarms (r2138)
External alarm 1 p2112 [C]
1
(1)
External alarm 2 p2116 [C]
(1)
1
External alarm 3 p2117 [C]
(1)
1
External fault 1 p2106 [C]
(1)
1
External fault 2 p2107 [C]
(1)
1
1
3
4
PROFIdrive-Bit
Bit No.
Control word, faults/alarms
0
Reserved
Reserved
1
Reserved
2
3
Reserved
4
Reserved
5
Reserved
Reserved
6
1 = Acknowledge fault
7
8
Reserved
9
Reserved
10
1 = External alarm 1 (A07850) effective
1 = External alarm 2 (A07851) effective
11
1 = External alarm 3 (A07852) effective
12
1 = External fault 1 (F07860) effective
13
14
1 = External fault 2 (F07861) effective
15
1 = External fault 3 (F07862) effective
5
fp_2546_97_51.vsd
09.12.2015
STW fault/alarm
r2138
r2138
r2138.7
r2138.10
r2138.11
r2138.12
r2138.13
r2138.14
r2138.15
6
7
Function diagram
G120 CU240B/E-2
V4.7.6
[2512.4], [8060.1]
[8065.1]
[8065.1]
[8065.1]
[2513.2], [8060.1]
[8060.1]
[8060.1]
8
- 2546 -