p9563[0...3]
SI Motion SLS-specific stop response (processor 1) / SI Mtn SLS stop P1
PM240
Access level: 3
PM250
Can be changed: C(95)
PM260
Unit group: -
CU240E-2_F
Min
CU240E-2_PN_F
0
CU240E-2_DP_F
Description:
Sets the SLS-specific stop response for the function "Safely Limited Speed" (SLS).
These settings apply to the individual limit values for SLS.
Value:
0:
1:
Index:
[0] = Limit value SLS1
[1] = Limit value SLS2
[2] = Limit value SLS3
[3] = Limit value SLS4
Dependency:
Refer to: p9531
Note:
SLS: Safely Limited Speed
p9564
SI Motion SDI tolerance (processor 1) / SI Mtn SDI tol P1
CU240E-2_F
Access level: 3
CU240E-2_PN_F
Can be changed: C(95)
CU240E-2_DP_F
Unit group: -
Min
0.001 [°]
Description:
Sets the tolerance for the function "Safe motion direction" (SDI).
This motion in the monitored direction is still permissible before safety message C01716 is initiated.
Dependency:
Refer to: p9565, p9566
Refer to: C01716
Note:
SDI: Safe Direction (safe motion direction)
p9565
SI Motion SDI delay time (processor 1) / SI Mtn SDI t P1
PM240
Access level: 3
PM250
Can be changed: C(95)
PM260
Unit group: -
CU240E-2_F
Min
CU240E-2_PN_F
0.00 [ms]
CU240E-2_DP_F
Description:
Sets the delay time for the function "Safe motion direction" (SDI).
After selecting the SDI function, then for a maximum of this time, motion in the monitored direction is permissible.
This time can therefore be used for braking any motion.
Dependency:
Refer to: p9564, p9566
Refer to: C01716
Note:
The set time is rounded internally to an integer multiple of the monitoring clock cycle.
SDI: Safe Direction (safe motion direction)
p9566
SI Motion SDI stop response (processor 1) / SI Mtn SDI Stop P1
PM240
Access level: 3
PM250
Can be changed: C(95)
PM260
Unit group: -
CU240E-2_F
Min
CU240E-2_PN_F
0
CU240E-2_DP_F
Description:
Sets the stop response for the function "Safe motion direction" (SDI).
This setting applies to both directions of motion.
SINAMICS G120 Control Units CU240B-2/CU240E-2
List Manual (LH11), 01/2016, A5E33839529
STOP A
STOP B
Calculated: -
Scaling: -
Unit selection: -
Max
1
Calculated: -
Scaling: -
Unit selection: -
Max
360.000 [°]
Calculated: -
Scaling: -
Unit selection: -
Max
600000.00 [ms]
Calculated: -
Scaling: -
Unit selection: -
Max
1
2 Parameters
2.2 List of parameters
Data type: Integer16
Dyn. index: -
Func. diagram: -
Factory setting
0
Data type: FloatingPoint32
Dyn. index: -
Func. diagram: 2824
Factory setting
12.000 [°]
Data type: FloatingPoint32
Dyn. index: -
Func. diagram: 2824
Factory setting
100.00 [ms]
Data type: Integer16
Dyn. index: -
Func. diagram: 2824
Factory setting
1
411