Siemens SINAMICS G120 List Manual page 737

Hide thumbs Also See for SINAMICS G120:
Table of Contents

Advertisement

Tec_ctrl sel bit 0 p2220 [C]
(0)
Tec_ctrl sel bit 1 p2221 [C]
(0)
Tec_ctrl sel bit 2 p2222 [C]
(0)
Tec_ctrl sel bit 3 p2223 [C]
(0)
1
2
Technology controller
Fixed value selection direct (p2216 = 1)
Tec_ctr FixVal sel
1 ... 2
p2216 [D] (1)
1
2
[7950]
1
2
[7950]
1
2
[7950]
1
2
[7950]
Tec_ctrl fix val1 [%]
p2201 [D] (10.00)
Tec_ctr fix val 2 [%]
p2202 [D] (20.00)
Tec_ctr fix val 3 [%]
p2203 [D] (30.00)
Tec_ctr fix val 4 [%]
p2204 [D] (40.00)
3
4
0 0 0 1
0 0 1 0
0 1 0 0
+
+
+
1 0 0 0
+
+
+
5
fp_7951_97_51.vsd
09.12.2015
Tec_ctr FixVal ZSW
r2225
r2225
Tec_ctr FixVal eff [%]
r2224
6
7
Function diagram
G120 CU240B/E-2
V4.7.6
.0
8
- 7951 -