Siemens SINAMICS G120 List Manual page 579

Hide thumbs Also See for SINAMICS G120:
Table of Contents

Advertisement

CU AO absVal act
0 ... 1
p0775 (0)
[0] (0)
CU AO S_src
p0771
[0]
0
y
(21[0])
1
x
1
y
x
2
x
• 100 %
1
x
2
Reference quantities
<2>
CU AO absVal act
0 ... 1
[1] (0)
p0775 (0)
CU AO S_src
0
p0771
[1]
y
(27[0])
(21[0])
1
<1>
For p0776 = 0, 2 the units are mA.
For p0776 = 1 the units are V.
<2>
The input signals are referred to the reference quantities p2000 ... r2004 (100 % = p200x).
<3>
Possible settings p0776[0] and p0776[1]:
= 0: 0 ... +20 mA
= 1: 0 ... +10 V
= 2: 4 ... +20 mA
1
2
Input/Output Terminals
CU240E-2: Analog outputs 0 ... 1 (AO 0 ... AO 1)
CU AO outp act ref [%]
CU AO char x1
r0772
[0]
-1000.00 ... 1000.00 [%]
p0777 (0.00)
CU AO T_smooth
0.0 ... 1000.0 [ms]
p0773 (0.0)
[0] (0)
<1>
CU AO char y2
-20.000 ... 20.000 [V]
p0780[0..1] (20.000)
[0] (20.000)
x
CU AO char y1
-20.000 ... 20.000 [V]
Smoothing
p0778[0..1] (0.000)
[0] (0.000)
<1>
[%]
CU AO outp act ref [%]
CU AO char x1
r0772
[1]
-1000.00 ... 1000.00 [%]
p0777 (0.00)
CU AO T_smooth
0.0 ... 1000.0 [ms]
[1] (0)
p0773 (0.0)
<1>
CU AO char y2
-20.000 ... 20.000 [V]
p0780[0..1] (20.000)
[1] (20.000)
x
CU AO char y1
-20.000 ... 20.000 [V]
Smoothing
p0778[0..1] (0.000)
[1] (0.000)
<1>
3
4
<3>
CU AO char x2
CU AO type
-1000.00 ... 1000.00 [%]
0 ... 2
[0] (0)
[0] (100)
p0779 (100.00)
p0776 (0)
y
0, 1
y
2
0
2
x
x
x
1
2
4 mA
[%]
y
1
Scaling
CU AO char x2
CU AO type
-1000.00 ... 1000.00 [%]
0 ... 2
[1] (0)
p0779 (100.00)
[1] (100)
p0776 (0)
y
0, 1
y
2
0
2
x
x
x
2
1
4 mA
[%]
y
1
5
fp_2261_97_02.vsd
09.12.2015
[0] (0)
<1>
CU AO U/I_outp
r0774
[0]
D
y
AO 0+
Kl. 12
A
GND
Kl. 13
[1] (0)
<1>
CU AO U/I_outp
r0774
[1]
AO 1+
Kl. 26
D
y
A
GND
Kl. 27
Sampling time of the AO: 4 ms
6
7
Function diagram
G120 CU240E-2
V4.7.6
Kl. = Terminal
8
- 2261 -

Advertisement

Table of Contents
loading

Table of Contents