Siemens SINAMICS G120 List Manual page 454

Hide thumbs Also See for SINAMICS G120:
Table of Contents

Advertisement

2 Parameters
2.2 List of parameters
p10023
SI Motion SS1 input terminal (processor 1) / SI Mtn SS1 F-DI P1
PM240
Access level: 3
PM250
Can be changed: C(95)
PM260
Unit group: -
CU240E-2_F
Min
CU240E-2_PN_F
0
CU240E-2_DP_F
Description:
Sets the fail-safe digital input (F-DI) for the "SS1" function.
Value:
0:
1:
2:
3:
255:
Dependency:
Refer to: p10123
Note:
If value = 0:
No terminal assigned, safety function always selected.
If value = 255:
No terminal assigned, safety function always deselected.
F-DI: Failsafe Digital Input
SS1: Safe Stop 1
p10026
SI Motion SLS input terminal (processor 1) / SI Mtn SLS F-DI P1
PM240
Access level: 3
PM250
Can be changed: C(95)
PM260
Unit group: -
CU240E-2_F
Min
CU240E-2_PN_F
0
CU240E-2_DP_F
Description:
Sets the fail-safe digital input (F-DI) for the "SLS" function.
Value:
0:
1:
2:
3:
255:
Dependency:
Refer to: p10126
Note:
If value = 0:
No terminal assigned, safety function always selected.
If value = 255:
No terminal assigned, safety function always deselected.
F-DI: Failsafe Digital Input
SLS: Safely Limited Speed
p10030
SI Motion SDI positive input terminal (processor 1) / SI SDI pos F-DI P1
PM240
Access level: 3
PM250
Can be changed: C(95)
PM260
Unit group: -
CU240E-2_F
Min
CU240E-2_PN_F
0
CU240E-2_DP_F
Description:
Sets the fail-safe digital input (F-DI) for the "SDI positive" function.
Value:
0:
1:
2:
3:
255:
454
Static selected
F-DI 0
F-DI 1
F-DI 2
Static deselected
Static selected
F-DI 0
F-DI 1
F-DI 2
Static deselected
Static selected
F-DI 0
F-DI 1
F-DI 2
Static deselected
Calculated: -
Scaling: -
Unit selection: -
Max
255
Calculated: -
Scaling: -
Unit selection: -
Max
255
Calculated: -
Scaling: -
Unit selection: -
Max
255
SINAMICS G120 Control Units CU240B-2/CU240E-2
Data type: Integer16
Dyn. index: -
Func. diagram: -
Factory setting
0
Data type: Integer16
Dyn. index: -
Func. diagram: -
Factory setting
0
Data type: Integer16
Dyn. index: -
Func. diagram: -
Factory setting
0
List Manual (LH11), 01/2016, A5E33839529

Advertisement

Table of Contents
loading

Table of Contents