Siemens SINAMICS G120 List Manual page 318

Hide thumbs Also See for SINAMICS G120:
Table of Contents

Advertisement

2 Parameters
2.2 List of parameters
Dependency:
The following applies: p2186 < p2185
Refer to: p2182, p2185
Refer to: A07926
Note:
The lower envelope curve is defined by p2186, p2188 and p2190.
p2187[0...n]
Load monitoring torque threshold 2 upper / M_thresh 2 upper
Access level: 3
Can be changed: U, T
Unit group: 7_1
Min
0.00 [Nm]
Description:
Sets the speed/torque envelope curve for load monitoring.
Dependency:
The following applies: p2187 > p2188
Refer to: p2183, p2188
Refer to: A07926
Note:
The upper envelope curve is defined by p2185, p2187 and p2189.
p2188[0...n]
Load monitoring torque threshold 2 lower / M_thresh 2 lower
Access level: 3
Can be changed: U, T
Unit group: 7_1
Min
0.00 [Nm]
Description:
Sets the speed/torque envelope curve for load monitoring.
Dependency:
The following applies: p2188 < p2187
Refer to: p2183, p2187
Refer to: A07926
Note:
The lower envelope curve is defined by p2186, p2188 and p2190.
p2189[0...n]
Load monitoring torque threshold 3 upper / M_thresh 3 upper
Access level: 3
Can be changed: U, T
Unit group: 7_1
Min
0.00 [Nm]
Description:
Sets the speed/torque envelope curve for load monitoring.
Dependency:
The following applies: p2189 > p2190
Refer to: p2184, p2190
Refer to: A07926
Note:
The upper envelope curve is defined by p2185, p2187 and p2189.
p2190[0...n]
Load monitoring torque threshold 3 lower / M_thresh 3 lower
Access level: 3
Can be changed: U, T
Unit group: 7_1
Min
0.00 [Nm]
Description:
Sets the speed/torque envelope curve for load monitoring.
Dependency:
The following applies: p2190 < p2189
Refer to: p2184, p2189
Refer to: A07926
Note:
The lower envelope curve is defined by p2186, p2188 and p2190.
318
Calculated: -
Scaling: -
Unit selection: p0505
Max
20000000.00 [Nm]
Calculated: -
Scaling: -
Unit selection: p0505
Max
20000000.00 [Nm]
Calculated: -
Scaling: -
Unit selection: p0505
Max
20000000.00 [Nm]
Calculated: -
Scaling: -
Unit selection: p0505
Max
20000000.00 [Nm]
SINAMICS G120 Control Units CU240B-2/CU240E-2
Data type: FloatingPoint32
Dyn. index: DDS, p0180
Func. diagram: 8013
Factory setting
10000000.00 [Nm]
Data type: FloatingPoint32
Dyn. index: DDS, p0180
Func. diagram: 8013
Factory setting
0.00 [Nm]
Data type: FloatingPoint32
Dyn. index: DDS, p0180
Func. diagram: 8013
Factory setting
10000000.00 [Nm]
Data type: FloatingPoint32
Dyn. index: DDS, p0180
Func. diagram: 8013
Factory setting
0.00 [Nm]
List Manual (LH11), 01/2016, A5E33839529

Advertisement

Table of Contents
loading

Table of Contents