2 Parameters
2.2 List of parameters
Index:
[0] = Number of error-free telegrams
[1] = Number of rejected telegrams
[2] = Number of framing errors
[3] = Number of overrun errors
[4] = Number of parity errors
[5] = Number of starting character errors
[6] = Number of checksum errors
[7] = Number of length errors
p2030
Field bus int protocol selection / Field bus protocol
CU240B-2_DP
Access level: 1
CU240E-2_DP
Can be changed: T
CU240E-2_DP_F
Unit group: -
Min
0
Description:
Sets the communication protocol for the field bus interface.
Value:
0:
3:
Notice:
For p0014 = 1, the following applies:
After the value has been modified, no further parameter modifications can be made and the status is shown in r3996.
Modifications can be made again when r3996 = 0.
Note:
Changes only become effective after POWER ON.
The parameter is not influenced by setting the factory setting.
p2030
Field bus int protocol selection / Field bus protocol
CU240B-2
Access level: 1
CU240E-2
Can be changed: T
CU240E-2_F
Unit group: -
Min
0
Description:
Sets the communication protocol for the field bus interface.
Value:
0:
1:
2:
Notice:
For p0014 = 1, the following applies:
After the value has been modified, no further parameter modifications can be made and the status is shown in r3996.
Modifications can be made again when r3996 = 0.
Note:
Changes only become effective after POWER ON.
The parameter is not influenced by setting the factory setting.
p2030
Field bus int protocol selection / Field bus protocol
CU240E-2 PN
Access level: 1
CU240E-2_PN_F
Can be changed: T
Unit group: -
Min
0
Description:
Sets the communication protocol for the field bus interface.
Value:
0:
7:
10:
Notice:
For p0014 = 1, the following applies:
After the value has been modified, no further parameter modifications can be made and the status is shown in r3996.
Modifications can be made again when r3996 = 0.
Note:
Changes only become effective after POWER ON.
The parameter is not influenced by setting the factory setting.
278
No protocol
PROFIBUS
No protocol
USS
Modbus RTU
No protocol
PROFINET
EtherNet/IP
Calculated: -
Scaling: -
Unit selection: -
Max
3
Calculated: -
Scaling: -
Unit selection: -
Max
2
Calculated: -
Scaling: -
Unit selection: -
Max
10
SINAMICS G120 Control Units CU240B-2/CU240E-2
Data type: Integer16
Dyn. index: -
Func. diagram: 9310
Factory setting
3
Data type: Integer16
Dyn. index: -
Func. diagram: 9310
Factory setting
0
Data type: Integer16
Dyn. index: -
Func. diagram: 9310
Factory setting
7
List Manual (LH11), 01/2016, A5E33839529