2.6
Quick commissioning (p0010 = 1)
The parameters required for the quick commissioning (p0010=1) are shown in the following
table:
.
Table 2-7
Par. no.
p0010
p0015
p0096
p0100
p0205
p0230
p0300
p0301
p0304
p0305
p0306
p0307
p0308
p0309
p0310
p0311
p0314
p0316
p0322
p0323
p0335
p0500
p0500
p0640
p0922
p0970
p1080
p1082
p1120
p1121
p1135
SINAMICS G120 Control Units CU240B-2/CU240E-2
List Manual (LH11), 01/2016, A5E33839529
Quick commissioning (p0010 = 1)
Name
Drive, commissioning parameter filter
Macro drive unit
Application class
IEC/NEMA mot stds
Power unit application
Drive filter type, motor side
Motor type selection
Motor code number selection
Rated motor voltage
Rated motor current
Number of motors connected in parallel
Rated motor power
Rated motor power factor
Rated motor efficiency
Rated motor frequency
Rated motor speed
Motor pole pair number
Motor torque constant
Maximum motor speed
Maximum motor current
Motor cooling type
Technology application
Technology application
Current limit
PROFIdrive telegram selection
Reset drive parameters
Minimum speed
Maximum rotation speed
Ramp-function generator ramp-up time
Ramp-function generator ramp-down time
OFF3 ramp-down time
2.6 Quick commissioning (p0010 = 1)
Access level
1
1
1
1
1
1
2
2
1
1
1
1
1
1
1
1
3
3
1
1
2
4
PM230
2
PM240
PM250
PM260, PM330
2
1
1
1
1
1
1
2
2 Parameters
Can be
changed
C(1)T
C,C(1)
C(1)
C(1)
C(1,2)
C(1,2)
C(1,3)
C(1,3)
C(1,3)
C(1,3)
C(1,3)
C(1,3)
C(1,3)
C(1,3)
C(1,3)
C(1,3)
C(1,3)
C(1,3)UT
C(1,3)
C(1,3)
C(1,3)T
C(1,5)T
C(1,5)T
C(1,3)UT
C(1)T
C(1,30)
C(1)T
C(1)T
C(1)UT
C(1)UT
C(1)UT
553