For bit 05:
The threshold value is set in p1226 and the delay time in p1228.
For bit 06:
The hysteresis is set in p2162.
For bit 07:
The threshold value is set in p2163 and the hysteresis is set in p2164.
For bit 08:
The threshold value is set in p2170 and the delay time in p2171.
For bit 09, 10:
The threshold value is set in p2172 and the delay time in p2173.
For bit 11:
The threshold value is set in p2179 and the delay time in p2180.
For bit 12:
The threshold value is set in p2182, the hysteresis in p2162, and the delay time (for canceling the signal) in p2152.
For bit 13:
Only for internal Siemens use.
r2198.0...13
CO/BO: Status word monitoring 2 / ZSW monitor 2
Access level: 3
Can be changed: -
Unit group: -
Min
-
Description:
Display and BICO output for the second status word of the monitoring functions.
Bit field:
Bit
00
01
02
03
04
05
06
07
08
09
10
11
12
13
Note:
For bit 10:
The torque threshold value 1 is set in p2174.
For bit 12:
This bit is reset after the fault cause disappears, even if the fault itself is still present.
r2199.0...11
CO/BO: Status word monitoring 3 / ZSW monitor 3
Access level: 3
Can be changed: -
Unit group: -
Min
-
Description:
Display and BICO output for the third status word of the monitoring functions.
Bit field:
Bit
00
01
SINAMICS G120 Control Units CU240B-2/CU240E-2
List Manual (LH11), 01/2016, A5E33839529
Signal name
|n_act| <= speed threshold value 5
|n_act| > speed threshold value 5
|n_act| <= speed threshold value 6
|n_act| > speed threshold value 6
|n_set| < p2161
n_set > 0
Motor blocked
Motor stalled
|I_act| < I_threshold value p2170
|M_act| > torque threshold value 1 and
n_set reached
|M_set| < torque threshold value 1
Load in the alarm range
Load in the fault range
|M_act| > torque threshold value 1
Signal name
|n_act| < speed threshold value 3
f or n comparison value reached or
exceeded
Calculated: -
Scaling: -
Unit selection: -
Max
-
1 signal
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Calculated: -
Scaling: -
Unit selection: -
Max
-
1 signal
Yes
Yes
2 Parameters
2.2 List of parameters
Data type: Unsigned16
Dyn. index: -
Func. diagram: 2536
Factory setting
-
0 signal
No
No
No
No
No
No
No
No
No
No
No
No
No
No
Data type: Unsigned16
Dyn. index: -
Func. diagram: 2537
Factory setting
-
0 signal
No
No
FP
8023
8023
8023
8023
8011
8011
8012
8012
8022
8023
8012
8013
8013
8023
FP
8010
8010
321