Bit field:
Bit
00
01
04
07
09
10
12
13
15
Notice:
For bit 07:
An internal event is displayed if a STOP A ... F is active.
The signal state behaves in an opposite way to the PROFIsafe Standard.
Note:
This parameter is only supplied with actual values if SI Motion functions are active. For Safety Integrated Basic
Functions the value is equal to zero.
p9761
SI password input / SI password inp
PM230_STO
Access level: 3
PM240
Can be changed: C, T
PM250
Unit group: -
PM260
Min
CU240E-2
0000 hex
CU240E-2_DP
CU240E-2 PN
CU240E-2_F
CU240E-2_PN_F
CU240E-2_DP_F
Description:
Enters the Safety Integrated password.
Dependency:
Refer to: F01659
Note:
It is not possible to change Safety Integrated parameters until the Safety Integrated password has been entered.
p9762
SI password new / SI password new
PM230_STO
Access level: 3
PM240
Can be changed: C(95)
PM250
Unit group: -
PM260
Min
CU240E-2
0000 hex
CU240E-2_DP
CU240E-2 PN
CU240E-2_F
CU240E-2_PN_F
CU240E-2_DP_F
Description:
Enters a new Safety Integrated password.
Dependency:
A change made to the Safety Integrated password must be acknowledged in the following parameter:
Refer to: p9763
SINAMICS G120 Control Units CU240B-2/CU240E-2
List Manual (LH11), 01/2016, A5E33839529
Signal name
STO or safe pulse suppression active
SS1 active
SLS active
Internal event
Active SLS stage bit 0
Active SLS stage bit 1
SDI positive active
SDI negative active
SSM (speed below limit value)
1 signal
Yes
Yes
Yes
No
Set
Set
Yes
Yes
Yes
Calculated: -
Scaling: -
Unit selection: -
Max
FFFF FFFF hex
Calculated: -
Scaling: -
Unit selection: -
Max
FFFF FFFF hex
2 Parameters
2.2 List of parameters
0 signal
No
No
No
Yes
Not set
Not set
No
No
No
Data type: Unsigned32
Dyn. index: -
Func. diagram: 2800
Factory setting
0000 hex
Data type: Unsigned32
Dyn. index: -
Func. diagram: 2800
Factory setting
0000 hex