2 Parameters
2.2 List of parameters
r1548[0...1]
CO: Stall current limit torque-generating maximum / Isq_max stall
Access level: 4
Can be changed: -
Unit group: 6_2
Min
- [Arms]
Description:
Displays the limit for the torque-generating current component using the stall calculation, the current limit of the
power unit as well as the parameterization in p0640.
Index:
[0] = Upper limit
[1] = Lower limit
Dependency:
Not visible with application class: "Standard Drive Control" (SDC, p0096 = 1)
p1552[0...n]
CI: Torque limit upper scaling without offset / M_max up w/o offs
Access level: 3
Can be changed: T
Unit group: -
Min
-
Description:
Sets the signal source for the scaling of the upper torque limiting to limit the speed controller output without taking
into account the current and power limits.
Dependency:
Not visible with application class: "Standard Drive Control" (SDC, p0096 = 1)
p1553[0...n]
Stall limit scaling / Stall limit scal
Access level: 4
Can be changed: U, T
Unit group: -
Min
80.0 [%]
Description:
Sets the scaling of the stall limit for the start of field weakening.
Dependency:
Not visible with application class: "Standard Drive Control" (SDC, p0096 = 1), "Dynamic Drive Control" (DDC, p0096
= 2)
Danger:
If the stall current limit is increased, then the q current setpoint can exceed the stall limit; as a consequence, a
hysteresis effect can occur when loading and unloading.
p1554[0...n]
CI: Torque limit lower scaling without offset / M_max low w/o offs
Access level: 3
Can be changed: T
Unit group: -
Min
-
Description:
Sets the signal source for the scaling of the lower torque limiting to limit the speed controller output without taking into
account the current and power limits.
Dependency:
Not visible with application class: "Standard Drive Control" (SDC, p0096 = 1)
p1560[0...n]
Moment of inertia estimator accelerating torque threshold value / J_est M thresh
Access level: 3
Can be changed: C(3), U, T
Unit group: -
Min
0.10 [%]
Description:
Sets the threshold for the accelerating torque for the moment of inertia estimator.
232
Calculated: -
Scaling: p2002
Unit selection: p0505
Max
- [Arms]
Calculated: -
Scaling: PERCENT
Unit selection: -
Max
-
Calculated: -
Scaling: -
Unit selection: -
Max
130.0 [%]
Calculated: -
Scaling: PERCENT
Unit selection: -
Max
-
Calculated: -
Scaling: -
Unit selection: -
Max
100.00 [%]
SINAMICS G120 Control Units CU240B-2/CU240E-2
Data type: FloatingPoint32
Dyn. index: -
Func. diagram: -
Factory setting
- [Arms]
Data type: U32 / FloatingPoint32
Dyn. index: CDS, p0170
Func. diagram: 6060
Factory setting
1
Data type: FloatingPoint32
Dyn. index: DDS, p0180
Func. diagram: -
Factory setting
100.0 [%]
Data type: U32 / FloatingPoint32
Dyn. index: CDS, p0170
Func. diagram: 6060
Factory setting
1
Data type: FloatingPoint32
Dyn. index: DDS, p0180
Func. diagram: -
Factory setting
10.00 [%]