[13] = Bit 13
[14] = Bit 14
[15] = Bit 15
Dependency:
Refer to: p2088, r2089
Notice:
The parameter may be protected as a result of p0922 or p2079 and cannot be changed.
p2083[0...15]
BI: Binector-connector converter status word 4 / Bin/con ZSW4
Access level: 3
Can be changed: U, T
Unit group: -
Min
-
Description:
Selects bits to be sent to the PROFIdrive controller.
The individual bits are combined to form free status word 4.
Index:
[0] = Bit 0
[1] = Bit 1
[2] = Bit 2
[3] = Bit 3
[4] = Bit 4
[5] = Bit 5
[6] = Bit 6
[7] = Bit 7
[8] = Bit 8
[9] = Bit 9
[10] = Bit 10
[11] = Bit 11
[12] = Bit 12
[13] = Bit 13
[14] = Bit 14
[15] = Bit 15
Dependency:
Refer to: p2088, r2089
p2084[0...15]
BI: Binector-connector converter status word 5 / Bin/con ZSW5
Access level: 3
Can be changed: U, T
Unit group: -
Min
-
Description:
Selects bits to be sent to the PROFIdrive controller.
The individual bits are combined to form free status word 5.
Index:
[0] = Bit 0
[1] = Bit 1
[2] = Bit 2
[3] = Bit 3
[4] = Bit 4
[5] = Bit 5
[6] = Bit 6
[7] = Bit 7
[8] = Bit 8
[9] = Bit 9
[10] = Bit 10
[11] = Bit 11
[12] = Bit 12
[13] = Bit 13
[14] = Bit 14
[15] = Bit 15
Dependency:
Refer to: p2088, r2089
SINAMICS G120 Control Units CU240B-2/CU240E-2
List Manual (LH11), 01/2016, A5E33839529
Calculated: -
Scaling: -
Unit selection: -
Max
-
Calculated: -
Scaling: -
Unit selection: -
Max
-
2 Parameters
2.2 List of parameters
Data type: U32 / Binary
Dyn. index: -
Func. diagram: 2472
Factory setting
0
Data type: U32 / Binary
Dyn. index: -
Func. diagram: 2472
Factory setting
0